bride de fixation BF 22

BF 22
  • Support pour tous types de capteurs de forme cylindrique à filet M22
  • Montage simple et calage précis
  • Grande plage de réglage (max. 25 mm)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF ::


Caractéristiques techniques  BF 22

Description produit
bride de fixation, 22 mm
Caractéristiques générales
Diamètre intérieur22 mm
Conditions environnantes
Température ambiante-25 ... 85 °C (-13 ... 185 °F)
Caractéristiques mécaniques
MatérialPBT
Couple de serrage des vis de fixationmax. 2,5 Nm
Dimensions60 mm x 45 mm x 29 mm

Classifications

SystemClasscode
ECLASS 11.027273701
ECLASS 10.0.127273701
ECLASS 9.027273701
ECLASS 8.027279202
ECLASS 5.127279202
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: BF 22

Design / Simulation: BF 22

Language Selection:
CADLangueType de fichierTaille
CAD 3-D / CAD 3-DALLSTP257 KB
CAD Portal / CAD PortalALLLINK---

Produits associés : BF 22

Accessoires de
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017Xfa
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017Xfa
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Dc (tc): IECEx TUR 21.0018X, Equipment protection level Mb: IECEx PTB 11.0037Xfa
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017Xfa
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Dc (tc): IECEx TUR 21.0018X, Equipment protection level Mb: IECEx PTB 11.0037Xfa
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: PG21, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Dc (tc): IECEx TUR 21.0018X, Equipment protection level Mb: IECEx PTB 11.0037Xfa