General specifications |
Switching function | Normally open/closed (NO/NC) |
Output type | Two-wire |
Rated operating distance | 40 mm |
Installation | non-flush |
Output polarity | AC/DC |
Assured operating distance | 0 ... 32.4 mm |
Actual operating distance | 36 ... 44 mm typ. 40 mm |
Reduction factor rAl | 0.37 |
Reduction factor rCu | 0.3 |
Reduction factor r304 | 0.73 |
Reduction factor rFe | 1 |
Reduction factor rBrass | 0.4 |
Output type | 2-wire |
Nominal ratings |
Switching frequency | AC, 0 ... 30 Hz DC, 0 ... 100 Hz |
Hysteresis | 1 ... 10 % typ. 5 % |
Reverse polarity protection | reverse polarity tolerant |
Short-circuit protection | pulsing |
Voltage drop | ≤ 5 V (typ. 2V) DC operation ≤ 8 V (typ. 3 V) AC operation |
Momentary current (20 ms, 0.1 Hz) | 0 ... 3000 mA |
Operating current | 5 ... 500 mA |
Rated operating current | 500 mA 50/60 Hz |
Lowest operating current | 5 mA |
Off-state current | ≤ 1.5 mA |
Usage category | AC12 , AC140 , DC12 , DC13 |
Time delay before availability | ≤ 300 ms |
Operating voltage indicator | LED, green |
Switching state indicator | LED, yellow |
Error indicator | flashes when overcurrent |
Functional safety related parameters |
MTTFd | 540 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications |
Rated operating voltage | 24 ... 250 V DC / 24 ... 230 V AC |
Operating voltage | 20 ... 275 V DC / 20 ... 253 V AC |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates |
Protection class | I |
| Rated insulation voltage | 230 V |
| Rated impulse withstand voltage | 2.5 kV |
UL approval | cULus Listed, General Purpose |
CCC approval | Ue 75VDC - 250VDC Ue 75VAC - 230VAC |
Ambient conditions |
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Pollution degree | 3 |
Mechanical specifications |
Connection type | terminal compartment |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Core cross section | up to 2.5 mm2 |
| Minimum core cross-section | without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2 |
| Maximum core cross-section | without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2 |
Housing material | PA 6.6 / metal |
Sensing face | PA 6.6 |
Housing base | metal / class I equipment with ground connection |
Degree of protection | IP67 |
Mass | 280 g |
Dimensions | |
| Height | 40 mm |
| Width | 40 mm |
| Length | 118 mm |
Note | Tightening torque: 1.8 Nm (housing) |