General specifications |
Detection range | 30 ... 650 mm |
Detection range min. | 30 ... 100 mm |
Detection range max. | 30 ... 650 mm |
Adjustment range | 100 ... 650 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Black-white difference (6 %/90 %) | < 6 % at 650 mm |
Diameter of the light spot | approx. 20 mm x 20 mm at a distance of 650 mm |
Opening angle | approx. 2 ° |
Ambient light limit | EN 60947-5-2 : 70000 Lux |
Functional safety related parameters |
MTTFd | 600 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: power on ; flashing (4 Hz) - short-circuit |
Function indicator | LED yellow: lights when object is detected ; flashing (approx. 4 Hz) at Pollution |
Control elements | Light-on/dark-on changeover switch |
Control elements | Sensing range adjuster |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Protection class | III |
Output |
Stability alarm output | 1 PNP, active when level falls below operating reserve after approx. 5 s. Immediately active if the beam is interrupted 4 times during the flashtime. |
Switching type | The switching type of the sensor is adjustable. The default setting is: Q - Pin4: PNP normally open / light-on Alarm output - Pin2: PNP normally open / light-on detected when soiled |
Signal output | 2 PNP outputs, short-circuit-proof, reverse polarity protection, surge-proof |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ≤ 1.5 V DC |
Switching frequency | 200 Hz |
Response time | 2.5 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , cable, fixed installation -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 / IP69 / IP69K |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector |
Material | |
| Housing | PC (Polycarbonate)
Retainer PA 6 (Polyamid) |
| Optical face | PMMA |
Mass | approx. 95 g |
Dimensions | |
| Height | 40 mm |
| Width | 76 mm |
| Depth | 71 mm |
Cable length | 0.3 m |