General specifications |
Detection range | 20 ... 2000 mm |
Detection range min. | 20 ... 200 mm |
Detection range max. | 20 ... 2000 mm |
Adjustment range | 200 ... 2000 mm |
Background suppression | max. + 10 % of the upper limit of the detection range |
Light source | IRED |
Light type | modulated infrared light , 880 nm |
Black-white difference (6 %/90 %) | < 40 % |
Diameter of the light spot | approx. 70 mm at a distance of 2000 mm |
Opening angle | transmitter 2° receiver 2° |
Ambient light limit | 50000 Lux |
Functional safety related parameters |
MTTFd | 620 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green |
Function indicator | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range |
Control elements | Sensing range adjuster , Light-on/dark-on changeover switch |
Electrical specifications |
Operating voltage | 12 ... 240 V AC/DC |
Power consumption | ≤ 3.5 VA |
Output |
Switching type | light/dark on, switchable (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.) |
Signal output | Relay, 1 alternator |
Switching voltage | max. 250 V AC/DC |
Switching current | max. 2 A |
Switching power | DC: max. 50 W AC: max. 500 VA |
Switching frequency | 25 Hz |
Response time | 20 ms |
Timer function | ON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable adjustment interval 0.1 ... 10 s |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
Protection class | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
UL approval | E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508.
|
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature | -40 ... 60 °C (-40 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2, insulation stripping 7.5 ... 8.5 mm, M16 x 1.5 cable gland |
Material | |
| Housing | Plastic ABS |
| Optical face | Plastic pane |
Mass | 112 g |
Dimensions | |
| Height | 88 mm |
| Width | 25.8 mm |
| Depth | 65.5 mm |