General specifications |
Measuring range | 60 ... 150 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | laser diode |
Light type | modulated visible red light |
Laser nominal ratings | |
| Note | LASER LIGHT , DO NOT STARE INTO BEAM |
| Laser class | 1 |
| Wave length | 680 nm |
| Beam divergence | > 5 mrad d63 d63 < 1 mm in the range of 50 mm ... 250 mm |
| Pulse length | 3 µs |
| Repetition rate | approx. 3 kHz |
| max. pulse energy | 15.2 nJ |
Angle deviation | max. +/- 1.5 ° |
Diameter of the light spot | approx. 2 mm at a distance of 150 mm |
Opening angle | approx. 1 ° |
Ambient light limit | EN 60947-5-2 : 30000 Lux |
Resolution | 0.1 mm |
Functional safety related parameters |
MTTFd | 560 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
Control elements | Teach-In key |
Control elements | 5-step rotary switch for operating modes selection |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Protection class | III |
Interface |
Interface type | IO-Link ( via C/Q = pin 4 ) |
IO-Link revision | 1.1 |
Device profile | Smart Sensor |
Device ID | 0x110906 (1116422) |
Transfer rate | COM2 (38.4 kBit/s) |
Min. cycle time | 3 ms |
Process data width | Process data input 3 Byte Process data output 2 Bit |
SIO mode support | yes |
Compatible master port type | A |
Output |
Switching type | The default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link Q2 - Pin2: NPN normally-open, PNP normally-closed |
Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ≤ 1.5 V DC |
Response time | 2 ms |
Conformity |
Communication interface | IEC 61131-9 |
Product standard | EN 60947-5-2 |
Laser safety | EN 60825-1:2014 |
Measurement accuracy |
Temperature drift | 0.05 %/K |
Warm up time | 5 min |
Repeat accuracy | ≤ 1 % |
Linearity error | ± 1 % |
Approvals and certificates |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
Ambient conditions |
Ambient temperature | 10 ... 60 °C (50 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 / IP69 / IP69K |
Connection | M8 x 1 connector, 4-pin |
Material | |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
Mass | approx. 10 g |
Dimensions | |
| Height | 44.5 mm |
| Width | 11 mm |
| Depth | 21.5 mm |