* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
NRB4-12GS40-E2-IO-V1
General specifications
Switching function
Normally open/closed (NO/NC) programmable
Output type
PNP
Rated operating distance
4 mm (factory setting)
Near operating distance
3 mm (can be activated by software)
Installation
flush
Output polarity
DC
Assured operating distance
0 ... 3.24 mm
Reduction factor rAl
1
Reduction factor rCu
1
Reduction factor r304
1
Reduction factor rSt37
1
Output type
3-wire
Nominal ratings
Operating voltage
10 ... 30 V DC
Switching frequency
0 ... 2000 Hz (switch point mode) 0 ... 125 Hz (window mode, switch point mode with stability alarm)
Hysteresis
typ. 3 %
Reverse polarity protection
reverse polarity protected
Short-circuit protection
pulsing
Voltage drop
≤ 0.5 V
Operating current
0 ... 200 mA
Off-state current
0 ... 0.5 mA typ. 60 µA at 25 °C
No-load supply current
≤ 15 mA
Time delay before availability
max. 150 ms
Constant magnetic field
200 mT
Alternating magnetic field
200 mT
Status indicator
Multihole-LED, yellow
Functional safety related parameters
MTTFd
362 a
Mission Time (TM)
20 a
Diagnostic Coverage (DC)
0 %
Interface
Interface type
IO-Link ( via C/Q = pin 4 )
IO-Link revision
1.1
Device ID
0x201101 (2101505)
Transfer rate
COM2 (38.4 kBit/s)
Min. cycle time
2.3 ms
Process data width
Process data input (control system side): 2 Bit Process data output (control system side): none
SIO mode support
yes
Compatible master port type
A
Compliance with standards and directives
Standard conformity
Standards
EN IEC 60947-5-2
Approvals and certificates
Protection class
II
Rated insulation voltage
60 V
Rated impulse withstand voltage
800 V
UL approval
cULus Listed, General Purpose Class 2 power source
CCC approval
CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F)
Storage temperature
-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type
Connector plug M12 x 1 , 4-pin
Housing material
Stainless steel 1.4305 / AISI 303
Sensing face
PBT
Degree of protection
IP67
Mass
25 g
Dimensions
Length
55 mm
Diameter
12 mm
Factory settings
Default setting
operating mode = switch point mode with stability alarm switching function = Normally open (NO) switching distance = 4 mm
General information
Scope of delivery
2 self locking nuts in scope of delivery
Classifications
System
Classcode
ECLASS 13.0
27274001
ECLASS 12.0
27274001
ECLASS 11.0
27270101
ECLASS 10.0.1
27270101
ECLASS 9.0
27270101
ECLASS 8.0
27270101
ECLASS 5.1
27270101
ETIM 9.0
EC002714
ETIM 8.0
EC002714
ETIM 7.0
EC002714
ETIM 6.0
EC002714
ETIM 5.0
EC002714
UNSPSC 12.1
39121550
Details:
NRB4-12GS40-E2-IO-V1
Function
Reduction factor 1 sensors reliably detect different metals with the same switch state.
The integrated IO-Link interface enables clear identification of the sensor and diagnosis of the sensor condition. When using the sensor, parameters and operating modes can be optimally configured specifically for the intended application. In addition to setting the switching function and a pulse extension, the user can select either switch point mode or window mode in combination with a stability alarm.
In switch point mode, the stability alarm signals the detection of an object in the area between the assured operating distance and operating distance sn. In window mode, it signals the detection of an object below the window between operating distance sn and the nearest operating distance. A stability alarm is displayed to the user via a flashing LED and process data.
Netlist price. Your individual price will be calculated during checkout.
In stock
Item 'PS1000-A6-24.5' added to cart!
100 V AC to 240 V AC wide-range input, Output 24 V DC, 5 A, 120 W, 1-phase, Housing width 32 mm, Efficiency up to 94.3 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC factory setting: 24.1 Vpa
Distance sensor, Medium design with versatile mounting options, Space-saving distance sensors in small standardized design, Multi Pixel Technology (MPT) - exact and precise signal evaluation, IO-Link interface for service and process datafa
Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here!
The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.
The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!
As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.