Serviceline Industrial Sensors
Phone: 330-486-0001
Fax: 330-405-4710
Serviceline Explosion Protection
Phone: 330-486-0002
Fax: 330-963-5827

Redundancy Module PS1000-D2-24.20.RM

PS1000-D2-24.20.RM
  • 24 V DC to 28 V DC input
  • 2 inputs with 1 output
  • Output 24 V DC, 20 A
  • Housing width 32 mm
  • Built-in decoupling mosfets for 1+1 and N+1 redundancy
  • Automatic load sharing
  • Reverse input polarity protection
  • Easy wiring: distribution terminal for negative pole included
  • Redundancy status indicator
  • Suitable for Zone 2/Div. 2 mounting
 Please contact the Serviceline for exact delivery estimation
156.00 USD
Netlist price. Your individual price will be calculated during checkout.
Unit Price 

Quantity

Free Shipping

Purchase on Account

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  PS1000-D2-24.20.RM

Electrical specifications
Voltage dropinput to output
0.1 ... 0.5 V at input 2 x 5 A
0.2 ... 0.5 V at input 2 x 10 A
0.24 ... 0.5 V at input 2 x 12 A
load share dependent
Power dissipation1.7 W no load
2.6 ... 4.7 W at input 2 x 5 A
5.6 ... 8.7 W at input 2 x 10 A
Input
Rated voltage24 ... 28 V
Voltage range18 ... 35 V DC
Current2 x 12 A at ambient temperature < 45 °C (113 °F)
2 x 10 A at ambient temperature 70 °C (158 °F)
2x 17 mA for max. 5 s
for lower output currents see technical information
Output
Voltage range24 ... 28 V DC
Current24 A at ambient temperature < 45 °C (113 °F)
20 A at ambient temperature < 70 °C (158 °F)
32.5 A for max. 5 s
max. 26 A in overload or short circuit mode (voltage < 6 V DC)
Fault indication output
Connectionterminals 13, 14 : relay contact load share
terminals 23, 24 : relay contact redundancy
Output typerelay contact load share
- contact is closed if the adjustment of the output voltages are sufficient
- contact is open if an even load share does not occur and readjustment of the output voltage is required
relay contact redundancy
- contact is closed if no fault is detected
- contact is open if one or both input voltages are below 22 V DC or above 30 V DC
- contact is open if the output current is higher than the adjusted value of the output current
- contact is open if an internal defect of the device is detected
Contact loadingmax. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load
min. 1 mA at 5 V DC
Galvanic isolation
Input/OutputSELV/PELV
Indicators/settings
Display elementsLED green: output status
- LED lights up if the output current is smaller than the adjusted value of the output current
LEDs green: load share status
- LEDs indicate the load share status between the two power supplies
LED green: redundancy status
- LED lights up if no fault is detected
- LED flashes if one ore both input values are below 22 V or above 30 V
- LED flashes if the output current is higher than the adjusted value of the output current
- LED flashes if an internal defect is detected
Control elementsrotary switch
Configurationsetting of the output current via rotary switch
- switch setting to 5 A in combination with two 5A power supplies (1+1 redundancy)
- switch setting to 10 A in combination with two 10A power supplies (1+1 redundancy)
- switch setting to 20 A for N+1 redundant systems
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUIEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4
Low voltage
Directive 2014/35/EUEN 61010-1
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000:2019
Conformity
Degree of protectionEN 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) , see technical information
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity5 ... 95 %, noncondensing
Shock resistance20 g , 11 ms or 30 g , 6 ms
Vibration resistance2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 2 g
Mechanical specifications
Housing materialaluminum alloy , galvanized steel
Degree of protectionIP20
Connection
Input/Outputscrew terminals
conductor cross section: max. 6 mm2 (AWG 20-10)
cable diameter: max. 2.8 mm, wire end ferrules included
stripped insulation length: 7 mm
tightening torque: max. 0.8 Nm
Relay contact outputspring terminals
conductor cross section: max. 1.5 mm2 (AWG 24-16)
cable diameter: max. 1.6 mm, wire end ferrules included
stripped insulation length: 7 mm
Massapprox. 310 g  
Dimensions32 x 124 x 117 mm (W x H x D) , without DIN mounting rail
Height124 mm
Width32 mm
Depth117 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
ATEX approval
ATEX certificateEPS 11 ATEX 1 312 X
ATEX markingEx-Hexagon II 3G Ex ec nC II T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-7:2016 , EN 60079-15:2010
International approvals
UL approvalE223176
IECEx approval
IECEx certificateIECEx EPS 20.0057X
IECEx markingEx ec nC IIC T4 Gc
StandardsIEC 60079-0:2011 , IEC 60079-7:2015 , IEC 60079-15:2010
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027040790
ECLASS 12.027040790
ECLASS 11.027040790
ECLASS 10.0.127040790
ECLASS 9.027040790
ECLASS 8.027049090
ECLASS 5.127049090
ETIM 9.0EC002542
ETIM 8.0EC002542
ETIM 7.0EC002542
ETIM 6.0EC002542
ETIM 5.0EC002542
UNSPSC 12.139121004

Details: PS1000-D2-24.20.RM

Function

The device is a redundancy module for building redundant power supply systems.

The device is equipped with 2 inputs and 1 output. Power supplies with an output current of up to 24 A and one output can be connected to the inputs. The power supplies can transmit a rated current of up to 20 A.

The both inputs are decoupled by MOSFETs. This reduces heat generation and voltage drop between input and output.

The device is mounted on a 35 mm DIN mounting rail according to EN 60715.

Informative Literature: PS1000-D2-24.20.RM

Language Selection:
LiteratureLanguageFile TypeFile Size
BrochureUSAPDF2134 KB

Product Documentation: PS1000-D2-24.20.RM

Language Selection:
Product informationLanguageFile TypeFile Size
Technical informationENGPDF3796 KB
Safety and Security Documentation
Instruction manual / BetriebsanleitungALLPDF225 KB
Instruction manual / BetriebsanleitungALLPDF294 KB

Design / Simulation: PS1000-D2-24.20.RM

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP4884 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ200 KB

Approvals: PS1000-D2-24.20.RM

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Bureau Veritas IECEx Certificate of ConformityIECEx EPS 20.0057XALLLINK---
Canada, USA CSA Hazardous LocationCoC 80059967ALLPDF84 KB
China SITIIAS CCC Ex Certificate2023122303116293 (Mannheim)ALLPDF519 KB
Europe Bureau Veritas ATEX Category 3 GEPS 11 ATEX 1 312XALLPDF1011 KB
US CA ULCoC E223176 RptRef E223176-20070416ALLPDF444 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4793ALLPDF73 KB
EU Declaration of Conformity (P+F)TDOC-4793AENGENGPDF185 KB

Associated Products: PS1000-D2-24.20.RM

Accessory of
238.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

100 V AC to 240 V AC wide-range input, Output 24 V DC, 10 A, 240 W, 1-phase, Housing width 39 mm, Efficiency up to 95.2 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC
factory setting: 24.1 Vpa
172.00  USD
Netlist price. Your individual price will be calculated during checkout.

In stock

100 V AC to 240 V AC wide-range input, Output 24 V DC, 5 A, 120 W, 1-phase, Housing width 32 mm, Efficiency up to 94.3 %, Minimal inrush current surge, DC OK relay contact, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Standard, Rated voltage: 24 V DC, Voltage range: 24 ... 28 V DC
factory setting: 24.1 Vpa