PROFINET IO to Modbus Gateway ICDM-RX/PN1-2DB9/RJ45-DIN

ICDM-RX/PN1-2DB9/RJ45-DIN
  • DIN-rail mounting and DB9 connectors
  • PROFINET IO to and from Modbus TCP, Modbus ASCII, Modbus RTU and Modbus to Modbus communication
  • Advanced Modbus gateway and routing capabilities
  • Data Mapping sub-system and a built-in Modbus concentrator
  • Web-based configuration
  • RS-232/422/485 software selectable interfaces
  • NEMA TS2 Certified

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Lataa koko tietolomake PDF-tiedostona:


Ote tietolomakkeesta: Tekniset tiedot  ICDM-RX/PN1-2DB9/RJ45-DIN

Tuotekuvaus
PROFINET IO to Modbus Gateway 2-port DIN rail DB9
General specifications
UL File NumberE360395
Functional safety related parameters
MTBF46.3 a
Indicators/operating means
LED indicationsee manual
Electrical specifications
Rated operating voltage5 ... 30 V DC
General informationRedundant power
Nominal voltage24 V DC
Interface
Interface typeSoftware selectable interfaces: RS-232 , RS-422 , RS-485 (2 and 4-wire)
Physical 2 x DB9
ProtocolMODBUS RTU
Supported baud rates300 bps to 230Kbps
Interface 1
Interface typeIndustrial Ethernet
Physical 1 x RJ45
ProtocolPROFINET IO
Additional protocolsARP, BOOTP, DHCP/RARP, HTTP, HTTPS, SSH, SSL/TLS, ICMP, RFC 1006 (ISO over TCP), SNMP (MIB-II), TCP/IP & UDP socket services, Telnet, and TFTP, and supports IP multicast data transmission
Transfer rate10/100 Mbps
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005 , EN 610006-4:2007 , EN 610006-4/A1:2011
RoHSEN IEC 63000:2018
Standard conformity
Degree of protectionNEMA TS2
Electrical safetyCSA C22.2 No. 60950 / UL60950
Emitted interferenceEN 61000-6-4, EN 55032, FCC Part 15 Subpart B, ICES-003, AS/NZS CISPR 32
Noise immunityEN 61000-6-2 , EN 55024
Ambient conditions
Ambient temperature-40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 95 %
Altitude0 ... 3048 m
Mechanical specifications
Degree of protectionIP20
ConnectionPower Supply: screw terminals
Fieldbus: 1 x RJ45
Inputs/outputs: 2 x DB9
Material
HousingPolyamide, UL94V-0
Mass136g
Dimensions
Height99.1 mm
Width22.9 mm
Length116.8 mm
Construction typeCabinet module
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027242608
ECLASS 12.027242608
ECLASS 11.027242608
ECLASS 10.0.127242608
ECLASS 9.027242608
ECLASS 8.027242608
ECLASS 5.127242608
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICDM-RX/PN1-2DB9/RJ45-DIN

Function

The ICDM-RX/EN1 gateway enables the connection of serial devices (RS-232 / RS-422 / RS-485) such as barcode scanners, RFID readers and weigh scales to both PROFINET IO and Modbus networks. It combines an PROFINET IO interface with a Modbus gateway functionality and a built-in programmable data mapping sub-system, that ties everything together and doubles as a Modbus concentrator. The embedded web pages provide extensive diagnostics, intuitive and flexible configuration options, secure interfaces and numerous maintenance options. The result is a highly flexible gateway that allows full integration of PROFINET IO controllers into simple or complex Modbus networks. PROFINET IO controllers such as PLCs, HMIs, SCADAs and OPC servers can communicate to almost any Modbus gateway or client, either locally or remotely.

Informative Literature: ICDM-RX/PN1-2DB9/RJ45-DIN

Language Selection:
LiteratureKieliTiedostotyyppiTiedoston koko
Product Information - Serial Gateways - DeviceMaster®ENGPDF1227 KB

Product Documentation: ICDM-RX/PN1-2DB9/RJ45-DIN

Language Selection:
ManualsKieliTiedostotyyppiTiedoston koko
Manual ICDM-RX/PN1ENGPDF7747 KB
ICDM-RX/ Hardware Installation and ConfigurationENGPDF12995 KB

Approvals: ICDM-RX/PN1-2DB9/RJ45-DIN

Language Selection:
CertificatesSertifikaatin nroKieliTiedostotyyppiTiedoston koko
Canada, USA UL ULE360395ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4273AALLPDF110 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7588ALLPDF105 KB
Australia Declaration of ConformityACMA Supplier’s declaration of conformityALLPDF298 KB

Software: ICDM-RX/PN1-2DB9/RJ45-DIN

Language Selection:
Device Description Files/DriversJulkaisutiedotTiedostotyyppiTiedoston koko
PROFINET GSDML and firmware files for ICDM-RX/PN1 Module / PROFINET GSDML und firmware Dateien für ICDM-RX/PN1 Module2024-09 v1.0.8ZIP1398 KB
Software Tools
PortVision DX v6.02 / PortVision DX v6.022020-08ZIP29584 KB

Liitännäistuotteet: ICDM-RX/PN1-2DB9/RJ45-DIN

Accessories
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

This free PDF white paper compares the different TCP-based communication protocols (AMQP, OPC UA, MQTT, REST API) that have found their way up and are considered the enablers of IIoT and Industry 4.0. Get your free download now!