Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 3 according to EN61496-1, 24 V DC supply voltage, 1 safe output contact, Performance level PLd (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 4-channel, Performance level (PL): PL d, Category: Cat. 3, Operating voltage: 24 V DC +20/-10 % 24 V AC ± 10 %, Connection: screw terminals , lead cross section 2 x 1 mm2fa |
|
|
|
Het product 'PSE4-SC-01' is nu toegevoegd aan uw watch list.
Het product 'PSE4-SC-01' staat al op uw watch list.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 4 according to EN61496-1, 24 V DC supply voltage, 2 safe output contacts, Performance level PLe (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 1-channel, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC +20/-10 %, Connection: screw terminals , Cable cross-section 0.2 ... 2.5 mm2fa |
|
|
|
Het product 'SB4 Cape' is nu toegevoegd aan uw watch list.
Het product 'SB4 Cape' staat al op uw watch list.
|
cover sheet, Cover for unused plug-in stations of the Safeboxfa |
|
|
|
Het product 'SB4 Housing 5' is nu toegevoegd aan uw watch list.
Het product 'SB4 Housing 5' staat al op uw watch list.
|
Empty housing for Evaluation unit SB4, Housing of the SafeBox with backplane for completionfa |
|
|
|
Het product 'SB4 Module 2E' is nu toegevoegd aan uw watch list.
Het product 'SB4 Module 2E' staat al op uw watch list.
|
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
Het product 'SB4 Module 4C' is nu toegevoegd aan uw watch list.
Het product 'SB4 Module 4C' staat al op uw watch list.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
Het product 'SB4 Module 4CP' is nu toegevoegd aan uw watch list.
Het product 'SB4 Module 4CP' staat al op uw watch list.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
Het product 'SB4 Module 4M' is nu toegevoegd aan uw watch list.
Het product 'SB4 Module 4M' staat al op uw watch list.
|
Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
Het product 'SB4 Module OR' is nu toegevoegd aan uw watch list.
Het product 'SB4 Module OR' staat al op uw watch list.
|
OSSD-R/Supply-module, Safety outputs OSSD, external status displays OSSD, Start/Restart disable , Operating mode can be selected by means of DIP switches, Relay monitor, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
Het product 'SB4-OR-4CP' is nu toegevoegd aan uw watch list.
Het product 'SB4-OR-4CP' staat al op uw watch list.
|
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, ± 20 %fa |
|
|
| |