Wireless sensor node with LoRaWAN interface, especially for monitoring the valve positions of 90° hand lever valves, for connecting up to 2 NAMUR single sensors |
Main sensor | ||
---|---|---|
Suitable sensors | Inductive sensors output type: NAMUR |
|
Number of connectable sensors | up to 2 | |
Query interval | - cylically according to the set LoRaWan transmission interval and or GPS acquistion interval - if required, additionally triggered by events at intervals of 1 min ... 24 h |
|
Integrated sensor technology | ||
GPS sensor | for geo-positioning | |
Acquisition interval | 30 min ... 24 h | |
Temperature sensor | ||
Resolution | 0.5 °C | |
Accuracy | ± 2 °C | |
Electrical specifications | ||
Battery type | high capacity lithium battery 3.6 V , 13000 mAh | |
Operating duration | battery lifetime approx. 10 years under Central European environmental conditions, 3 measurements and 3 wireless transmission per day with sufficient network coverage. | |
Interface 1 | ||
Interface type | Bluetooth 5.0 LE | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 2402 ... 2480 MHz | |
Interface 2 | ||
Interface type | LoRaWAN | |
Specification | LoRaWAN interface specification V1.0.3 | |
Device type | LoRaWAN class A device | |
Transmitter frequency | 868 MHz | |
Transmitter radiated power | + 14 dBm | |
Frequency range | 863 ... 870 MHz (Europe) |
|
Transmission interval | 10 min ... 24 h | |
Inputs | ||
Number of channels | 2 | |
Connection | max. cable length 10 m | |
Input type | NAMUR | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 301 489-1 V2.2.3:2019 EN 301 489-3 V2.1.1:2019 EN 301 489-17 V3.2.4:2020 EN 301 489-19 V2.1.1:2019 |
|
Radio and telecommunication terminal equipment | ||
Directive 2014/53/EU | EN 300 220-2 V3.1.1:2017 EN 300 328 V2.2.2:2019 EN 303 413 V1.1.1:2017 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 63000:2018 | |
Conformity | ||
Mech. capacity | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Shock resistance | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Vibration resistance | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Climatic conditions | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | socket | |
Degree of protection | IP66 / IP67 | |
Material | ||
Housing | PC (UL94-V0) | |
Socket | brass, nickel-plated | |
Socket | ||
Threading | M12 x 1 | |
Number of pins | 4 | |
Mass | 570 g | |
Dimensions | ||
Height | 74 mm | |
Width | 81 mm | |
Length | 182 mm | |
Factory settings | ||
Default setting | LoRaWAN transmission interval = 24 h LoRaWAN Downlink channel = enabled LoRaWAN Downlink acknowledgement = enabled GPS = disabled |
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
The wireless sensor node is used to remotely monitor the valve positions of 90°-hand lever valves. The valve position(s) and other measurement and status data from the connected sensors and the wireless sensor node are recorded at adjustable time intervals and transmitted to the remote station in the LoRaWAN network. The data is available there for display or further processing.
The wireless sensor node can be accessed remotely from the LoRaWAN network via the downlink channel of the wireless sensor node in order to query or adjust device parameter values. Parameterization can also be carried out via the additional Bluetooth interface in the sensor node using a mobile device (smartphone or tablet) and the corresponding WILSEN app.
Literature | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
Application Report - Smart Position Feedback from Hand Lever Valves | ENG | 322 KB |
Product information | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
Brief Instructions - Battery Lifetime Calculator for WILSEN Devices | ENG | 148 KB | |
Downlink Description WS-VAL-*-F406-B41-*-02-* | ENG | 487 KB | |
Integration into a LoRa Network for WS-UCC*-F406-B15-B41-01-02 | ENG | 1833 KB | |
Payload Description (Uplink) for WS-VAL-*-F406-B41-*-02-* | ENG | 208 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 546 KB |
CAD | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 10341 KB |
Declaration of Conformity | Sertifika No. | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-7394A | ALL | 38 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|