Fabrika Otomasyonu
Proses Otomasyonu

5500 manifold, FM & CSA certified 5500-MAN-CD01-*

5500-MAN-CD01-*
  • Suitable for Class I,II/Div. 1 & 2 for hazardous locations
  • Certifications for FM and CSA
  • Manifold combines the solenoid valve for purging and needle valve for pressurization in one housing
  • Suitable for steel or plastic tubing
  • Mounting hardware, pneumatic fittings and tubing included

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Tam veri sayfasını PDF olarak indirin:


Veri sayfası alıntısı: Teknik veriler  5500-MAN-CD01-*

General specifications
Operating modeautomatic purging
Series5500
Hazardous environmentgas or dust
Supply
Rated power24 VDC: 4.6 W
120 VAC: 6.8 VA, 60 Hz
230 VAC: 6.8 VA, 60 Hz
Voltage tolerance: +/-10%
Electrical specifications
Fuse ratingDC: 500 mA
AC: 80 mA
(fuse rating on 5500 control unit)
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.4 bar (20 psi) to 8.2 bar (120 psi)
Purge flow ratesolenoid valves : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.25
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Connection typePneumatic
Input port: 3/8 inch Tube compression fitting
Output port: 3/8" Tube compression fitting

Electrical connection
½" NPTF thread connection w/ 24" (0.61m) flying leads
Degree of protectiontype 7 & 9
Material
Housing: anodized aluminum
3/8" compression fittings: 316 stainless steel
Pressure ports: 3/8" NPTF
Bulkhead fitting: 316 stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: UL recognized type 4X
Mass1250 g (2.8 lb)
Dimensionssee dimensions
International approvals
FM approvalFM3006713
Explosion proof: Class I, Divison 1, Group A-D, T4, Ta = 60C
DIP: Class II, Division 1, Groups F+G, T4, Ta = 60C
Nonincendive: Class I, Division 2, Groups A-D, T4, Ta = 60C

Suitable for Class II, Division 2, Groups F+G, T4, Ta = 60C
CSA approvalCSA 202633
Class I, Division 1, Groups A-D: Class II, Groups E,F,G
Class I, Division 2, Groups A-D

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127291390
ECLASS 9.027291390
ECLASS 8.027291390
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: 5500-MAN-CD01-*

Function

The 5500-MAN-CD01- * combines a solenoid valve for purging and a needle valve for pressurization in one manifold design. When the valve is energized, the solenoid valve opens and allows for a high flow of protective gas into the enclosure. When the valve is deenergized, the flow through the internal needle valve is adjustable by a flathead screw driver through the needle stem located on the manifold. The solenoid valve is used for purging, leakage compensation, and temperature control by signals from user defined points on the 5500 control unit.

Mounting hardware includes 3/8" tube compression fittings mounted on the manifold for input and output flow, 3/8" tube compression bulkhead fitting for getting flow into the enclosure and certified sealing washers with bolts to mount the manifold to the enclosure. Also included is 1 meter of 3/8" poly tubing with 3/8" poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing.

The 5500 valve system works with the 5500 control unit and EPV-5500 vents. The 5500 Series system has FM and CSA certification for Class/Division installation, see model number key for proper manifold selection.

For ATEX and IECEx applications look the model number key proper manifold selection.

Design / Simulation: 5500-MAN-CD01-*

Dil Seçeneği:
CADDilDosya TipiDosya Boyutu
CAD 2-D / CAD 2-DALLZIP222 KB

Approvals: 5500-MAN-CD01-*

Dil Seçeneği:
CertificatesSertifika No.DilDosya TipiDosya Boyutu
Canada CSA202633ALLLINK---
USA FM110221ALLLINK---

İlişkili Ürünler: 5500-MAN-CD01-*

Accessory of
Bebco EPS 5500 series Type Z & Ex pzc purge and pressurization control unitpa
pa
pa

Get to know the smartest way to ensure hazardous location protection and configure your individual purge and pressurization system!

Our interactive app gives you a step-by-step programming simulation for your purge and pressurization system. Download the free-of-charge app for iOS or Android devices now …

Ex p Purge Units

Discover the all-new 5500 Series. These compact purging units enable fully automatic protection.