Your technical, product, or application questions answered in one business day* by our team of experts.
! Please fill in all fields before submitting your question. Pepperl+Fuchs values your privacy. Please read our privacy policy.
* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
IC-KP2-2HRX-2V1
Product Description
Control interface unit IDENTControl Compactwith serial interface RS-232 and RS-485
General specifications
Number of read/write heads
max. 2 alternatively 1 read/write head and 1 trigger sensor
UL File Number
E87056
MTBF
80 a (Operation at +40 °C)
Indicators/operating means
LEDs 1, 2
Status indicator for read/write heads
LEDs CH1, CH2
green: read head detected red: Configuration error
LED PWR/ERR
green: power on red: Hardware fault
LED TxD
green: flashes in rhythm with the transmitted data
LED RxD
green: flashes in rhythm of receiving data
Electrical specifications
Rated operating voltage
20 ... 30 V DC , PELV
Ripple
≤ 10 % at 30 V DC
Current consumption
≤ 4 A incl. read/write heads
Power consumption
2 W Without read/write heads
Galvanic isolation
basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Interface type
serial
Physical
RS-485
Protocol
ASCII
Transfer rate
1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Interface 2
Interface type
serial
Physical
RS 232
Protocol
ASCII
Transfer rate
1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU
EN 61000-6-2 EN 61000-6-4
RoHS
Directive 2011/65/EU (RoHS)
IEC/EN 63000
Standard conformity
Degree of protection
IEC 60529
Ambient conditions
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F)
Storage temperature
-40 ... 85 °C (-40 ... 185 °F)
Climatic conditions
air humidity max. 96 % Salt spray resistant to EN 60068-2-52
Shock and impact resistance
Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
The RFID identification system IDENTControl Compact from Pepperl+Fuchs offers a vast number of benefits compared to other systems, thanks to its innovative design. The control interfaces IDENTControl and IDENTControl Compact make up the core of the system.
With its integrated interfaces to all commercially available fieldbus systems such as PROFIBUS, PROFINET, Ethernet, EtherCAT, CC-Link, serial connections (RS 232 or RS 485) and numerous connection options for read/write heads available for frequency ranges LF, HF and UHF, the IDENTControl Compact control interface can be easily and flexibly adapted to your requirements.
LEDs on the front of the housing indicate bus communication, connected read/write heads and active read/write commands. Reliability of the application is further increased by using trigger sensors.
The system is equally suited for use in control cabinets and field use in IP67. The interface to the higher-level fieldbus is integrated in the housing, and all connections are designed such that they are pluggable. This enables simple installation and quick, problem-free replacement in case of device failure. The consistent EMC design, with metal housing, grounding and shielded wires, offers a high degree of reliability.
Register for an introduction to RFID technology training session with our Product Manager. Sessions are one-on-one and last around an hour. All skill levels are welcome.
Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …