Tuotekuvaus |
---|
1001B Series pressurization system |
General specifications | ||
---|---|---|
Series | 1001B | |
System | Type Y Purge , Type Z Purge | |
Hazardous environment | gas | |
Electrical specifications | ||
Connection | Terminal blocks | |
Output | ||
Output I | -WPS- | |
Output type | Switch contacts | |
Contact loading | 120 VAC @ 15 A | |
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Pressure requirement | 5 - 120 psi (With EPV-3 vent. Systems installed without vent must be equipped with redundant regulator set to 5 psi max.) |
|
Safe pressure | Setpoint: 1.0" (25.4 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr) |
|
Ambient conditions | ||
Ambient temperature | -29 ... 49 °C (-20.2 ... 120.2 °F) | |
Mechanical specifications | ||
Connection type | System supply fitting: 3/8" tube fitting Enclosure supply fitting: 3/8" tube fitting Enclosure reference fitting: 1/4" tube fitting Switch conduit port size: 1/2" FPT |
|
Material | Regulator body: zinc w/enamel finish Regulator handle: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Tube fitting: 316 ss forged body Tubing: 316 ss 1/4" .035 welded System nameplate: silk screened Lexan® & ss Fastener hardware: alum. & stainless steel Mounting plate: 316 14 ga #3 brush ss EXP pressure switch body: anodized cast aluminum Enclosure warning nameplate: silk screened ss |
|
Mass | 1001B-LPS-* 3.2 kg (7 lb) 1001B-WPS-* 5.4 kg (12 lb) |
|
International approvals | ||
FM approval | Type Y LPS: Class II, Division 1, Groups E, F, and G WPS: Class II, Division 1, Groups E, F, and G Type Z LPS: Class II, Division 2, Groups E, F, and G WPS: Class II, Division 2, Groups E, F, and G |
|
UL approval | ||
cULus | Type Y LPS: Class II, Division 1, Groups E, F, and G WPS: Class II, Division 1, Groups E, F, and G Type Z LPS: Class II, Division 2, Groups E, F, and G WPS: Class II, Division 2, Groups E, F, and G |
System | Classcode |
---|---|
ECLASS 13.0 | 27180508 |
ECLASS 12.0 | 27180508 |
ECLASS 11.0 | 27180508 |
ECLASS 10.0.1 | 27180508 |
ECLASS 9.0 | 27180508 |
ECLASS 8.0 | 27180508 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121301 |
Model 1001B is an enclosure pressurization system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed (protected) enclosure(s), in order to prevent combustible dust accumulation by maintaining a "safe" (1.0") pressure. This process reduces the hazardous (classified) area rating within the enclosure(s), in accordance with the NEC - NFPA 70, Article 500, NFPA 496 and ISA 12.4.
Brief Instructions | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Installation and Operation Manual: Model 1001B Type Y or Z Pressurization System | ENG | 2407 KB |
Certificates | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
Canada, USA FM | CoC 3018335 | ALL | 433 KB | |
UL Hazardous Location | E184741 (RFPW, RFPW7) | ALL | 193 KB |