Bebco EPS 5500 series Type Z & Ex pzc purge and pressurization control unit |
General specifications | ||
---|---|---|
Operating mode | fully automatic (FA) | |
Series | 5500 | |
System | Type Z Purge ; Ex pzc Purge | |
Number of volume exchanges | 4 ... 19 | |
Hazardous environment | gas or dust | |
Supply | ||
Rated voltage | 100 ... 240 V AC, 0.05 A, 50 ... 60 Hz 20 ... 30 V DC, 0.2 A |
|
Power consumption | 100 ... 240 V AC - 2.3 VA (without digital valve) 20 ... 30 V DC - 2.5 W (without digital valve) |
|
Electrical specifications | ||
Fuse rating | F2: AC: max. 2 A DC: max. 3.15 A F1: AC: max. 0.08 A DC: max. 0.5 A |
|
Input | ||
Input I | Temperature, up to 2 RTDs per unit | |
Connection | Pt100, 2-wire-connection | |
Input type | temperature input Input accuracy: 2.5% of the measurement value + PT100 error |
|
Input II | 1 Bypass | |
Connection | passive contact (switch) | |
Input type | mechanical contact | |
Output | ||
Output I | ||
Connection | K1, terminals: K1/N0, K1/N0 | |
Output type | enclosure power, (1) SPST | |
Inrush current | 6 A | |
Contact loading | 6 A at 250 V AC , 30 V DC resistive load, 6 A at 30 V DC | |
Output II | ||
Connection | K2, terminals: K2 (NO, C, NC) | |
Output type | alarm, (1) SPDT | |
Inrush current | 3 A | |
Contact loading | 3 A at 250 V AC , 30 V DC resistive load, 3 A at 30 V DC | |
Output III | ||
Connection | digital valve, terminals SV | |
Output type | (1) SPST, powered contacts from supply 5.0 A at 250 VAC or 30 VDC |
|
Inrush current | 5 A | |
Indicators/settings | ||
LED indication | Membrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor |
|
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Safe pressure | - gas 0.7 mbar (0.3 in w.c.) - dust 1.6 mbar (0.65 in w.c.) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 40 °C (-4 ... 104 °F) at T6 -20 ... 60 °C (-4 ... 140 °F) at T4 |
|
Relative humidity | 5 ... 95 %, non-condensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Connection type | High pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF |
|
Cable gland | Cable size M12 diameter 3 - 6.5 mm M20 diameter 10 - 12 mm RTD/Bypass: (3) M12x1.5 K1, K2, SV: 'P_C' (3) M20x1.5 |
|
Degree of protection | Type 4X, IP66 | |
Material | Housing: 316 stainless steel Cable Gland: 316 stainless steel or Nickel Plated Brass Pressure Ports: 316 stainless steel Membrane Pad: Autotex F200XE O-ring: EPDM |
|
Mass | approx. 2.7 kg (6 lb) | |
Dimensions | 165 x 124 x 90 mm (6.5 x 4.9 x 3.5 in) | |
Height | 203 mm | |
Width | 165 mm | |
Depth | 105 mm | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 14 ATEX 1282X | |
Marking | II 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) II 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version) |
|
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-15:2019 , EN 60079-2:2014 , EN 60079-7:2015+A1:2018 , EN 60079-31:2014 |
|
International approvals | ||
UL approval | ||
cULus | UL File E184741 Class I, Division 2, Groups A, B, C, D T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Division 2, Groups F, G, T4 (-20 °C ≤ Ta ≤ 60 °C) Class I, Division 2, Groups A, B, C, D T6 (-20 °C ≤ Ta ≤ 40 °C) Class II, Division 2, Groups F, G T6 (-20 °C ≤ Ta ≤ 40 °C) |
|
IECEx approval | IECEx UL 14.0019X Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version) |
|
General information | ||
Supplementary information | Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27180508 |
ECLASS 12.0 | 27180508 |
ECLASS 11.0 | 27180508 |
ECLASS 10.0.1 | 27180508 |
ECLASS 9.0 | 27180508 |
ECLASS 8.0 | 27180508 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121301 |
The 5500 series purge/pressurization system consists of the control unit with a user interface in a 316 stainless steel enclosure that works in conjunction with the EPV vents and pneumatic solenoid valves or manual valves form a certified purge and pressurization system for enclosures. The user interface is menu driven and easily guides users through custom programing for their applications. (2) RTD’s can be connected to inputs and the user can select temperature ranges for controlling and alarming critical temperatures through a set of contacts and energizing a solenoid valve for displacing air within the enclosure or operate cooling or heating functions. Enclosure pressure and leakage can be monitored. In the event of a loss in pressure a solenoid valve can engage to restore the defined pressure settings and/or alarm for pressure loss.
The 5500 series purge and pressurization system has NEC, CEC, CCC, ATEX and IECEx third-party certifications for Class I, II/Div. 2 and Zone 2/22
Product information | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Basic Explosion Protection Compendium - Type of Protection "Purge and Pressurization" | ENG | 3860 KB | |
Brief Instructions | |||
Purge & Pressurization Smart App - Users Guide / Purge & Pressurization Smart App - Users Guide | ALL | 1771 KB | |
5500 Series Purge and Pressurization Quick Guide | ENG | 1140 KB | |
Safety and Security Documentation | |||
Käyttöohje | FIN | 157 KB | |
Manuals | |||
User Manual for the 5500 Series Purge and Pressurization System | ENG | 2706 KB |
CAD | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
DWG and STP files for the Purge 5500, External Mount Version "EXT1" / CAD 2-D | ALL | ZIP | 2832 KB |
DWG and STP files for the Purge 5500, Internal Mount Version "PM01" and "PM02" / CAD 2-D | ALL | ZIP | 2800 KB |
Certificates | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
ATEX Certificate | DEMKO 14 ATEX 1282X | ALL | 129 KB | |
China SITIIAS CCC Ex Certificate | 2020322304002488 (Katy, TX USA) | ALL | 1580 KB | |
IECEx Certificate of Conformity | IECEx UL 14.0019X | ALL | LINK | --- |
India PESO (India) CCOE | A/P/HQ/KA/104/5761 (P471351) | ALL | 563 KB | |
Korea KOSHA | 16-AV4BO-0139X | ALL | 530 KB | |
UL Hazardous Location | E184741 (RFPW, RFPW7) | ALL | LINK | 431 KB |
Control Drawings | ||||
5500 Pz, Type Z Purge System control drawing / Control drawing UL | ALL | 130 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-B020F | ALL | 162 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-B0G0A | ALL | 159 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|