Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Descargue la hoja de datos completa en PDF:
Descripción del producto |
---|
KE control cabinet module 2 analog inputs |
General specifications | ||
---|---|---|
Node type | A/B node | |
AS-Interface specification | V3.0 | |
Required gateway specification | ≥ V3.0 | |
UL File Number | E223772 | |
Indicators/operating means | ||
LED FAULT | error display; LED red red: communication error red flashing: peripheral error or address 0 |
|
LED INT | Internal input supply active; LED green | |
LED PWR | AS-Interface voltage; LED green green: AS-Interface voltage OK green flashing: peripheral error or address 0 |
|
LED AUX | ext. auxiliary voltage UAUX ; LED green | |
LED -/OK | Status input signal; LED green Off: Not connected (Only current module) On: Signal within measuring range Flashing: Signal outside measuring range |
|
LED U/I | Current or voltage module; Green LED Off: Voltage input On: Current input |
|
Electrical specifications | ||
Auxiliary voltage (output) | 24 V DC ± 15 % PELV (protection class 3 according to VDE 0106/IEC 364-4-41) |
|
Insulation voltage | ≥ 500 V | |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
Rated operating current | ≤ 80 mA | |
Input | ||
Input voltage | For voltage module: ≤ 25 V per input | |
Number/Type | 2 analog inputs Current: 4 ... 20 mA voltage: 0 ... 10 V |
|
Supply | from AS-Interface or from external auxiliary voltage as required UAUX | |
Input current | For current module: ≤ 40 mA per input | |
Input resistance | For current module: 50 Ω For voltage module: 100 kΩ |
|
Switching point | Changeover current/voltage module: current module with Iin ≥ 1 mA voltage module with Uin ≥ 1 V |
|
Resolution | 14 Bit / 1 µA (Current module) or 14 bit / 1 mV (Voltage module) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61131-2:2007 | |
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
AS-Interface | EN 62026-2:2013 | |
Programming instructions | ||
Profile | S-7.A.9 | |
IO code | 7 | |
ID code | A | |
ID2 code | 9 | |
Data bits (function via AS-Interface) | The transfer of the data value is based on AS-Interface Profile 7.A.9. | |
Parameter bits (programmable via AS-i) | function | |
P0 | mains power frequency filter P0=1, 50 Hz filter active P0=0, 60 Hz filter active |
|
P1 | P1=1, normal operating mode P1=0, both channels in current mode and without recognition of wire breakage |
|
P2 | Message of peripheral error P2=1, peripheral error is reported P2=0, peripheral error is not reported |
|
Ambient conditions | ||
Ambient temperature | 0 ... 70 °C (32 ... 158 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
|
Material | ||
Housing | PA 66-FR | |
Mass | 350 g | |
Dimensions | ||
Height | 85 mm | |
Width | 22.5 mm | |
Length | 99 mm | |
Mounting | DIN mounting rail |
System | Classcode |
---|---|
ECLASS 13.0 | 27242601 |
ECLASS 12.0 | 27242601 |
ECLASS 11.0 | 27242601 |
ECLASS 10.0.1 | 27242601 |
ECLASS 9.0 | 27242601 |
ECLASS 8.0 | 27242601 |
ECLASS 5.1 | 27242601 |
ETIM 9.0 | EC001596 |
ETIM 8.0 | EC001596 |
ETIM 7.0 | EC001596 |
ETIM 6.0 | EC001596 |
ETIM 5.0 | EC001596 |
UNSPSC 12.1 | 39121535 |
Brief Instructions | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
Mounting Instruction VBA-2E-KE2-I/U-V3.0 / Montageanleitung VBA-2E-KE2-I/U-V3.0 | ALL | 842 KB | |
Manuals | |||
Manual VBA-2E-G4-I; VBA-2E-G4-U; VBA-2A-G4-I; VBA-2A-G4-U; VBA-4E-G4-Pt100; VBA-2A-KE2-I/U; VBA-2E-KE2-I/U; VBA-2E-KE2-I/U-V3.0 | ENG | 4051 KB |
CAD | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1916 KB |
Certificates | Número de Certificado | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|---|
Canada, USA UL | CoC 20141115-E223772 | ALL | 342 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2448C | ALL | 109 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
Módulo de armario de conmutación AS-Interface KE5 – Manejo sencillo y manipulación mejorada
El diseño único de la carcasas del nuevo módulo de armario de conmutación KE5 permite una visibilidad superior y simplifica el montaje, cableado y mantenimiento dentro de los armarios de conmutación y cajas de conexiones.