Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Descargue la hoja de datos completa en PDF:
Descripción del producto |
---|
Universal distance sensor, measurement to reflector, IO-Link interface, measuring method PRT, measuring range up to 60 m, red laser light, laser class 1, push-pull output, fixed cable with M12 plug |
General specifications | ||
---|---|---|
Measurement range | 0.2 ... 60 m | |
Reference target | OFR-500/500 | |
Light source | laser diode | |
Light type | modulated visible red light | |
Laser nominal ratings | ||
Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
Laser class | 1 | |
Wave length | 660 nm | |
Beam divergence | 2 mrad | |
Pulse length | 4 ns | |
Repetition rate | 300 kHz | |
max. pulse energy | < 1.3 nJ | |
Measuring method | Pulse Ranging Technology (PRT) | |
Max. Motion velocity | 10 m/s | |
Diameter of the light spot | < 20 mm at 10 m | |
Ambient light limit | 10000 Lux | |
Resolution | 1 mm | |
Temperature influence | < 0.25 mm/K | |
Functional safety related parameters | ||
MTTFd | > 300 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
|
Teach-in indicator | Teach-In : LED yellow/green; equiphase flashing; 2,5 Hz Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC 18 ... 30 V from IO-Link |
|
Ripple | 10 % within the supply tolerance | |
No-load supply current | < 25 mA at 24 V Operating voltage | |
Protection class | III | |
Time delay before availability | < 900 ms | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D Smart Sensor - SSP 4.2.1 |
|
Process data | Input 6 Byte - measurement value 4 Byte - scaling factor 8 Bit - signal quality 2 Bit - switching signal 1 1 Bit - switching signal 2 1 Bit - diagnosis signals n Bit - additional signals n Bit Output 2 Bit - sensor control function 1 Bit - evaluation freeze 1 Bit |
|
Vendor ID | 1 (0x0001) | |
Device ID | 1121041 (0x111B11) | |
Transfer rate | COM2 (38.4 kBit/s) | |
Min. cycle time | 4 ms | |
SIO mode support | yes | |
Output | ||
Switching type | The default setting is: C/Q - Pin4: push-pull output, IO-Link Q2 - Pin2: push-pull output |
|
Signal output | 2x push-pull outputs, reverse polarity protected, surge-proof | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 3 ms | |
Conformity | ||
Communication interface | IEC 61131-9 / IO-Link V1.1.3 | |
Product standard | EN 61000-6-2, EN 61000-6-3 | |
Laser safety | EN 60825-1:2014 | |
Measurement accuracy | ||
Warm up time | 5 min | |
Measured value output | 1 ms | |
Average data age | 3 ms (default), 6 ms , 12 ms , 25 ms , 50 ms , 100 ms , adjustable | |
Absolute accuracy | typ. ± 20 mm (including influence of temperature) | |
Repeat accuracy | < 6 mm | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
FDA approval | IEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 | |
Ambient conditions | ||
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 / IP69 / IP69K | |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 37 g | |
Dimensions | ||
Height | 50.6 mm | |
Width | 15 mm | |
Depth | 41.7 mm | |
Factory settings | ||
Switching output 1 | Q1: switching signal high-active , Window mode 6000 ... 9000 mm | |
Switching output 2 | Q2: switching signal high-active , Window mode 4000 ... 8000 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27270916 |
ECLASS 12.0 | 27270916 |
ECLASS 11.0 | 27270801 |
ECLASS 10.0.1 | 27270801 |
ECLASS 9.0 | 27270801 |
ECLASS 8.0 | 27270801 |
ECLASS 5.1 | 27270801 |
ETIM 9.0 | EC001825 |
ETIM 8.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 5.0 | EC001825 |
UNSPSC 12.1 | 41111613 |
Los sensores ópticos de esta serie son los primeros dispositivos en ofrecer una solución completa con un diseño estándar de tamaño medio, desde el sensor fotoeléctrico de barrera unidireccional hasta el sensor de medición de distancia. Como resultado de este diseño, los sensores permiten realizar prácticamente todas las tareas de automatización habituales.
Toda la serie posibilita la comunicación de los sensores a través de IO-Link.
El sensor de distancia se basa en la tecnología de rango de pulso (PRT) de Pepperl+Fuchs.
Para rangos pequeños y grandes, estos sensores de distancia son muy precisos, lo que los convierte en ideales para tareas de posicionamiento. El diodo láser rojo es claramente visible, lo que permite la alineación directa del dispositivo para un funcionamiento fiable.
Literature | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
Application Report - Compact Design and Precise Distance Measurement up to 60 m | ENG | 332 KB | |
Product information R10x and R20x Series Standard Housings - All Sensing Modes | ENG | 2583 KB |
Product information | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Parameter Information | |||
IO-Link parameter documentation OMR60M-R200-2EP-IO* series | ENG | 420 KB |
Certificates | Número de Certificado | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|---|
Canada USA UL Ordinary Location | UL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3 | ALL | 1806 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) | TDOC-7485_SPA | SPA | 219 KB | |
UK Declaration of Conformity (P+F) | TDOC-7486_ENG | ENG | 195 KB |
Device Description Files/Drivers | Liberar Info | Tipo de archivo | Tamaño |
---|---|---|---|
IODD for OMR60M-R200-L series / IODD für OMR60M-R200-L Serie | V1.01.000 / 2024-07-09 | ZIP | 427 KB |
DTM / DTM | ZIP | 16922 KB | |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
Por primera vez, se dispone de una completa gama de soluciones con tecnologías innovadoras y principios funcionales fotoeléctricos, todo integrado en un mismo producto. Los usuarios se beneficiarán de un principio de funcionamiento uniforme en toda la gama. Descubra las series R100, R101, R103, R200 y R201…