Línea de servicio de Sensores Industriales
+52 55 5636-0970
+52 55 5636-0975
Atención al cliente para protección contra explosiones
+52 55 5636-0970
+52 55 5636-0975

PROFINET IO Gateway ICDM-RX/PN-ST/RJ45-DIN

ICDM-RX/PN-ST/RJ45-DIN
  • Web-based configuration
  • DIN-rail mounting and screw terminal connections
  • RS-232/422/485 software selectable interfaces
  • NEMA TS2 Certified
  • PROFINET IO: connect serial and Ethernet TCP/IP devices to PROFINET IO controllers and TCP/IP applications

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  ICDM-RX/PN-ST/RJ45-DIN

Descripción del producto
PROFINET IO Gateway 1-port DIN Rail Screw Terminal
General specifications
UL File NumberE360395
MTBF61.4 a
Indicators/operating means
LED indicationsee manual
Electrical specifications
Rated operating voltage5 ... 30 V DC
General informationRedundant power
Nominal voltage24 V DC
Interface
Interface typeSoftware selectable interfaces: RS-232 , RS-422 , RS-485 (2 and 4-wire)
Physical 1 x screw terminal
ProtocolRaw serial
Supported baud rates300 bps to 230Kbps
Interface 1
Interface typeIndustrial Ethernet
Physical 1 x RJ45
ProtocolPROFINET IO
Additional protocolsARP, BOOTP, DHCP/RARP, HTTP, HTTPS, SSH, SSL/TLS, ICMP, RFC 1006 (ISO over TCP), SNMP (MIB-II), TCP/IP & UDP socket services, Telnet, and TFTP, and supports IP multicast data transmission
Transfer rate10/100 Mbps
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005 , EN 610006-4:2007 , EN 610006-4/A1:2011
RoHSEN IEC 63000:2018
Standard conformity
Degree of protectionNEMA TS2
Electrical safetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
Emitted interferenceEN 61000-6-4, EN 55032, FCC Part 15 Subpart B, ICES-003, AS/NZS CISPR 32
Noise immunityEN 61000-6-2
Ambient conditions
Ambient temperature-40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 95 %
Altitude0 ... 3048 m
Mechanical specifications
Degree of protectionIP20
ConnectionPower Supply: screw terminals
Fieldbus: 1 x RJ45
Inputs/outputs: 9-pin screw terminal block
Material
HousingPolyamide, UL94V-0
Mass113.4g
Dimensions
Height99.1 mm
Width22.9 mm
Length119.3 mm
Construction typeCabinet module
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027242608
ECLASS 12.027242608
ECLASS 11.027242608
ECLASS 10.0.127242608
ECLASS 9.027242608
ECLASS 8.027242608
ECLASS 5.127242608
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICDM-RX/PN-ST/RJ45-DIN

Informative Literature: ICDM-RX/PN-ST/RJ45-DIN

Seleccionar idioma:
LiteratureIdiomaTipo de archivoTamaño
Product Information - Serial Gateways - DeviceMaster®ENGPDF1227 KB

Product Documentation: ICDM-RX/PN-ST/RJ45-DIN

Seleccionar idioma:
ManualsIdiomaTipo de archivoTamaño
ICDM-RX/PN Installation and ConfigurationENGPDF7872 KB
ICDM-RX/ Hardware Installation and ConfigurationENGPDF12995 KB

Design / Simulation: ICDM-RX/PN-ST/RJ45-DIN

Seleccionar idioma:
CADIdiomaTipo de archivoTamaño
CAD 3-D / CAD 3-DALLSTP3200 KB

Approvals: ICDM-RX/PN-ST/RJ45-DIN

Seleccionar idioma:
CertificatesNúmero de CertificadoIdiomaTipo de archivoTamaño
Canada, USA UL ULE360395ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4274AALLPDF110 KB
Australia Declaration of ConformityACMA Supplier's declaration of conformityALLPDF302 KB

Software: ICDM-RX/PN-ST/RJ45-DIN

Seleccionar idioma:
Device Description Files/DriversLiberar InfoTipo de archivoTamaño
PROFINET firmware and GSDML files for ICDM-RX/PN modules / PROFINET-Firmware und GSDML-Dateien für ICDM-RX/PN-Module2024-09 - v3.4.10ZIP1340 KB
Software Tools
PortVision DX v6.02 / PortVision DX v6.022020-08ZIP29584 KB

Productos asociados: ICDM-RX/PN-ST/RJ45-DIN

Accessories
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Descarga gratuita: Documento técnico sobre protocolos de comunicación basados en TCP (PDF)

Este documento técnico gratuito en formato PDF compara los diferentes protocolos de comunicación basados ​​en TCP (AMQP, OPC UA, MQTT, REST API) que se han abierto camino y se consideran los habilitadores de IIoT e Industria 4.0. Descárguelo ahora de forma gratuita.