Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Last ned komplett datablad som PDF:
Produktbeskrivelse |
---|
Vibration sensor with IO-Link and programmable switching output or analog current output |
General specifications | ||
---|---|---|
Type | Vibration sensor | |
Measuring technology | MEMS capacitive | |
Series | Performance Plus Line | |
Measured variable | Vibration velocity Vibration acceleration Bearing status parameter Crest factor Temperature |
|
Measuring range | ||
Vibration velocity | 0 ... 128 mm/s | |
Vibration acceleration | 0 ... 34 g rms | |
Vibration acceleration | 0 ... 48 g peak value per 1 s | |
Vibration acceleration | -48 ... 48 g by means of BLOB transfer | |
Bearing status parameter | 1 ... 4 see section characteristic curve |
|
Crest factor | 0 ... 100 | |
Temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Measurement accuracy | Vibration velocity: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s Vibration acceleration: ± 0.01 g (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 |
|
Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
Resolution | Vibration velocity: 0.01 mm/s Vibration acceleration: 0.01 g Bearing status parameter: 0.01 |
|
Frequency range | Vibration acceleration a-raw: 1 ... 12 kHz , by means of BLOB transfer Vibration velocity rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration rms: 1 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration a-peak: 10 ... 10 kHz Crest factor: 10 ... 10 kHz Bearing status parameter: 10 ... 10 kHz , acc. to DIN ISO 13373-3 |
|
Averaging time | for v-rms: 2 s for a-rms: 2 s |
|
Sampling rate | Vibration acceleration a-raw: 64 kHz , programmable Vibration velocity rms: 8 Hz Vibration acceleration rms: 8 kHz Vibration acceleration a-peak: 32 Hz Crest factor: 32 Hz Bearing status parameter: 32 kHz |
|
Functional safety related parameters | ||
MTTFd | 329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Fusing | external fuse is required: 1 A , fast acting , 30 V DC | |
Operating voltage | 18 ... 30 V DC | |
Current consumption | max. 320 mA | |
Power consumption | max. 10 W | |
Time delay before availability | ≤ 3.6 s | |
Surge protection | up to 2 kV | |
Interface | ||
Interface type | IO-Link (via C/Q = Pin 4) | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D , BLOB transfer | |
Process data | Input 24 Byte measurement channels: -rms value velocity - peak value acceleration - rms value acceleration - temperature - crest factor - bearing status parameter per measurement channel: - measurement value 2 Byte - scaling 8 Bit - switching signals 2 Bit status data |
|
Vendor ID | 1 (0x0001) | |
Device ID | 5308673 (0x510101) | |
Transfer rate | COM3 (230.4 kbits/s) | |
Min. cycle time | 3.8 ms | |
SIO mode support | yes | |
Compatible master port type | Class A Class B (use 3-pole adapter or 3-wire cable) |
|
BLOB size | 1.28 MByte , programmable | |
BLOB segments | 200 Byte per request and BLOB segment respectively | |
Output 1 | ||
Output type | C/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable) | |
Switching function | Normally open/closed (NO/NC) | |
Operating current | ≤ 100 mA | |
Short-circuit protection | yes | |
Output 2 | ||
Output type | I/Q - pin 2 (parameterizable as analog current output or switching signal) - I: analog output for the measured variable, current 4 ... 20 mA - Q: switching signal of the measured variable is parameterizable, PNP normally open |
|
Switching function | Normally open/closed (NO/NC) | |
Operating current | ≤ 120 mA for switching signal | |
Voltage drop | < 2 V | |
Output current | 4 ... 20 mA at analog output | |
Load resistor | ≤ 500 Ω at analog output | |
Short-circuit protection | yes | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66, IP67 | |
Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 12000 Hz | |
Vibration evaluation | DIN ISO 10816/20816 , DIN ISO 13373-3 | |
Approvals and certificates | ||
UL approval | ||
Ordinary Location | E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request |
|
Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) | |
Ambient conditions | ||
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | plug | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Degree of protection | IP66 / IP67 only in connected state | |
Connector | ||
Threading | M12 | |
Number of pins | 4 | |
Mass | approx. 100 g | |
Dimensions | ||
Length | 72.5 mm | |
Diameter | 23.8 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27271103 |
ECLASS 12.0 | 27201406 |
ECLASS 11.0 | 27201406 |
ECLASS 10.0.1 | 27201406 |
ECLASS 9.0 | 27201406 |
ECLASS 8.0 | 27201406 |
ECLASS 5.1 | 27201406 |
ETIM 9.0 | EC004309 |
ETIM 8.0 | EC004309 |
ETIM 7.0 | EC002959 |
ETIM 6.0 | EC002959 |
ETIM 5.0 | EC001758 |
UNSPSC 12.1 | 41114624 |
The vibration sensor determines the vibration quantity using rms (root mean square) averaging. This form of quadratic averaging or pre-filtering enables precise trend statements about the condition of the application.
The integrated IO-Link interface provides an optimal adaption to different applications through parameterization and process data transmission for condition monitoring.
Using BLOB transfer, larger amounts of data can be transferred, which enables high-frequency vibration acceleration measurements. You can use this measured data as the basis for a frequency analysis using a fast Fourier transform (FFT).
The simple mounting allows for commissioning in any application.
Literature | Språk | Filtype | Filstørrelse |
---|---|---|---|
Product Overview - Vibration Sensors | ENG | 1351 KB | |
Application Report - Servicing Mobile Concrete Mixers According to Actual Needs | ENG | 169 KB |
Product information | Språk | Filtype | Filstørrelse |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 252 KB | |
Safety and Security Documentation | |||
Bruksanvisningen | NOR | 147 KB | |
Manuals | |||
Manual VIM3*-IO-* Vibration Sensors | ENG | 2011 KB | |
Parameter Information | |||
IO-Link Parameter Datasheet VIM32PP-E7DC8-0RE-IO-1V1401 | ENG | 843 KB |
CAD | Språk | Filtype | Filstørrelse |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2046 KB |
CAD 3-D / CAD 3-D | ALL | STP | 2534 KB |
Certificates | Sertifikatnummer | Språk | Filtype | Filstørrelse |
---|---|---|---|---|
IO-Link Manufacturer Declaration | CERT-7546A | ALL | 265 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-6865 | ALL | 325 KB | |
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-7705 | ALL | 236 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-6866 | ALL | 249 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitätserklärung (P+F) | DOC-7706 | ALL | 201 KB |
Device Description Files/Drivers | Frigivelsesinfo | Filtype | Filstørrelse |
---|---|---|---|
IODD for VIM32PP-*D*-0*-*01 / IODD für VIM32PP-*D*-0*-*01 | V2.00.000 / 2024-09-09 | ZIP | 237 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|