Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Last ned komplett datablad som PDF:
Produktbeskrivelse |
---|
Vibration sensor with switching output and analog current output |
General specifications | ||
---|---|---|
Type | Vibration sensor | |
Measuring technology | MEMS | |
Series | Performance Line | |
Measured variable | Vibration velocity | |
Measuring range | ||
Vibration velocity | 0 ... 25 mm/s | |
Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s |
|
Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
Frequency range | 10 ... 1000 Hz | |
Averaging time | for v-rms: 2 s | |
Functional safety related parameters | ||
MTTFd | 329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Fusing | external fuse is required: 1 A , fast acting , 30 V DC | |
Operating voltage | 18 ... 30 V DC | |
Current consumption | max. 220 mA | |
Power consumption | max. 6.6 W | |
Time delay before availability | 2 s (rms filter is calculated intially with measurement data before they are available at the output) | |
Surge protection | up to 2 kV | |
Output 1 | ||
Output type | analog output, current output of the vibration variable |
|
Output current | 4 ... 20 mA | |
Load resistor | ≤ 500 Ω | |
Output 2 | ||
Output type | PNP | |
Switching function | Normally closed (NC) | |
Operating current | ≤ 100 mA | |
Voltage drop | < 2 V | |
Switching threshold | 2.5 mm/s ( 10 % of the measuring range ) | |
Preset response time | 2 s (minimum time for a vibration event above the switching threshold so that the output switches) | |
Short-circuit protection | yes | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66, IP67 | |
Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz | |
Vibration evaluation | DIN ISO 10816/20816 | |
Approvals and certificates | ||
UL approval | ||
Ordinary Location | E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request |
|
Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) | |
Ambient conditions | ||
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | plug | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Degree of protection | IP66 / IP67 only in connected state | |
Connector | ||
Threading | M12 | |
Number of pins | 4 | |
Mass | approx. 100 g | |
Dimensions | ||
Length | 72.5 mm | |
Diameter | 23.8 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27271103 |
ECLASS 12.0 | 27201406 |
ECLASS 11.0 | 27201406 |
ECLASS 10.0.1 | 27201406 |
ECLASS 9.0 | 27201406 |
ECLASS 8.0 | 27201406 |
ECLASS 5.1 | 27201406 |
ETIM 9.0 | EC004309 |
ETIM 8.0 | EC004309 |
ETIM 7.0 | EC002959 |
ETIM 6.0 | EC002959 |
ETIM 5.0 | EC001758 |
UNSPSC 12.1 | 41114624 |
The vibration sensor determines the vibration quantity using rms (root meas square) averaging. This form of quadratic averaging or pre-filtering enables precise trend statements about the condition of the application.
In addition, a switching output with preset switching characteristics is included. This means a permanent monitoring of the vibration measured value is not required, because a necessary maintenance of the plant is signalized directly. The switching characteristics are provided with a preset response time. Thus, the output is only set if the vibration event lasts longer than this time. Short-time vibration events are hence filtered out.
The simple mounting allows for commissioning in any application.
Literature | Språk | Filtype | Filstørrelse |
---|---|---|---|
Product Overview - Vibration Sensors | ENG | 1351 KB | |
Application Report - Servicing Mobile Concrete Mixers According to Actual Needs | ENG | 169 KB |
Brief Instructions | Språk | Filtype | Filstørrelse |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 252 KB | |
Safety and Security Documentation | |||
Bruksanvisningen | NOR | 147 KB | |
Manuals | |||
Manual VIM3* Vibration Sensors | ENG | 1870 KB |
CAD | Språk | Filtype | Filstørrelse |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2534 KB |
Certificates | Sertifikatnummer | Språk | Filtype | Filstørrelse |
---|---|---|---|---|
Canada, USA UL Ordinary Location | E468231 | ALL | 610 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-5656A | ALL | 449 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-5657A | ALL | 255 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|