Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Activator BT65-F31K2-RG-EN-01

BT65-F31K2-RG-EN-01
  • High-visibility valve position display
  • Protection against contamination and damage
  • Two actuation targets in two levels with 5° setting grid
  • Suitable for right and left rotating drives

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  BT65-F31K2-RG-EN-01

Produktbeskrivelse
Activator for F31K2 series including protective housing
General specifications
Ring diametermax. 65 mm
Spring ring heightmax. 6 mm
Nominal ratings
Valve status indicatorred = CLOSED
green = OPEN
Ambient conditions
Ambient temperature-40 ... 75 °C (-40 ... 167 °F)
Mechanical specifications
Shaft diameter≤ 49 mm
Shaft height20 mm and 30 mm
Mounting hole pattern30 x 80 mm
Material
HousingPC
ActuatorPA
Spacer diskPA (1 unit, 10 mm strong)
Mounting screwStainless steel 1.4401 / AISI 316
Activation targetStainless steel 1.4305 / AISI 303 (integrated)
General information
Scope of delivery1 screw M6 x 30
1 screw M6 x 40
1 Activator for F31K2 series
1 Distance disc
1 Protective Cover
Fixing screws

Classifications

SystemClasscode
ECLASS 13.027274002
ECLASS 12.027274002
ECLASS 11.027270103
ECLASS 10.0.127270103
ECLASS 9.027270103
ECLASS 8.027270191
ECLASS 5.127270191
ETIM 9.0EC001487
ETIM 8.0EC001487
ETIM 7.0EC001487
ETIM 6.0EC001487
ETIM 5.0EC003015
UNSPSC 12.131251509

Details: BT65-F31K2-RG-EN-01

Design / Simulation: BT65-F31K2-RG-EN-01

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP7202 KB
CAD Portal / CAD PortalALLLINK---

Relaterte produkter: BT65-F31K2-RG-EN-01

Accessory of
Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUR 17.0055X, Equipment protection level Gb: IECEx TUR 17.0055Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUR 17.0055X, Equipment protection level Gb: IECEx TUR 17.0055Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 X, Ambient temperature: -40 ... 75 °C (-40 ... 167 °F) , restriction for use in hazardous area, see instruction manualfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 X, Ambient temperature: -40 ... 75 °C (-40 ... 167 °F) , restriction for use in hazardous area, see instruction manualfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: Two-wire, Installation: for non-flush mounting, Output polarity: DC, Output type: 2x 2-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: Two-wire with minimum off-state current, Installation: for non-flush mounting, Output polarity: DC, Output type: 2x 2-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 Xfa