Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

AS-Interface actuator module VBA-4A-G10-E2J-1M-V15-G

VBA-4A-G10-E2J-1M-V15-G
  • Ultra-compact enclosure
  • Gold-plated and machined contacts
  • One piece housing
  • Degree of protection IP68 / IP69K
  • Direct connection via cable outlet

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  VBA-4A-G10-E2J-1M-V15-G

Produktbeskrivelse
G10 ultra compact module, 4 outputs
General specifications
Node typeA/B node
AS-Interface specificationV3.0
Required gateway specificationV3.0
UL File NumberE223772 "For use in NFPA 79 Applications only"
MTBF382 a
Indicators/operating means
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: Output supply overload
LED AS-iAS-Interface voltage; LED green
Electrical specifications
Rated operating voltage18.5 ... 31.6 V from AS-Interface
Rated operating current≤ 40 mA / max. 150 mA
Protection classIII
Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV)
Output
Number/Type4 electronic outputs, PNP, overload and short-circuit proof
Supplyfrom AS-Interface
Voltage≥ (Ue - 7.0 V)
Current loading capacity≤ 100 mA Total current , overload and short-circuit protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2004
Emitted interferenceEN 61000-6-4:2011
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005 EN 62026-2:2013
Programming instructions
ProfileS-7.A.7
IO code7
ID codeA
ID1 code7
ID2 code7
Data bits (function via AS-Interface)InputOutput
D0 - OUT1
D1 - OUT2
D2 - OUT3
D3 - OUT4
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2Synchronous mode
P2 = 0 synchronous mode on
P2 = 1 synchronous mode off (default settings)
P3not used
Approvals and certificates
UL approvalcULus Listed, Type 1 enclosure
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks
10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Mechanical specifications
Degree of protectionhousing: IP67
IP67 / IP68 / IP69K with flat cable VAZ-FK-S-*
M12 socket: IP67/IP68/IP69K
ConnectionAS-Interface: AS-Interface flat cable
Outputs & matching connector: M12 connector, 5-pin, A-coded, acc. to IEC 61076-2-101:2012
Material
ContactsCuSn / Au
HousingPBT PC
BodyPUR, black
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter∅4.8 mm
Colorblack
Cores5 x 0.34 mm2
Length1 m
Mass81 g
Tightening torque, fastening screws1.65 Nm
Tightening torque, cable gland0.4 Nm
Dimensions
Height21.5 mm
Width27.7 mm
Length40.5 mm

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: VBA-4A-G10-E2J-1M-V15-G

Function

The AS-Interface G10 ultra-compact module is suitable for the remote connection of signal elements within very limited space. Up to 3 light and one siren element can be connected to the module. The one-piece enclosure has the protection degree IP68/IP69K.

The AS-Interface flat cable is contacted via pointy, gold-plated contact pins. The exact location of the pins on the lead is ensured by the swivel mechanism. Actuators are connected to the module via M12 sockets.

Multiple LEDs indicate the current status of the AS-Interface strand and are used for diagnosis.

Product Documentation: VBA-4A-G10-E2J-1M-V15-G

Velg språk:
Brief InstructionsSpråkFiltypeFilstørrelse
Instruction leaflet / BeipackzettelALLPDF185 KB

Approvals: VBA-4A-G10-E2J-1M-V15-G

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
Worldwide AS-International Association AS-Interface126901ALLPDF117 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2573BALLPDF115 KB

Relaterte produkter: VBA-4A-G10-E2J-1M-V15-G

Accessories

Stack light siren element 8 tonefa
Adapter cable G10 module/hand-held programming devicefa
Stack light audible alarmfa
Stack light audible alarmfa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

Dette gratis PDF-dokumentet sammenligner de forskjellige TCP-baserte kommunikasjonsprotokollene (AMQP, OPC UA, MQTT, REST API) som har funnet veien opp og regnes som muliggjørerne for IIoT og Industry 4.0. Last ned gratis nå!

AS-Interface Switch Cabinet Module KE5 – Simple Handling and Improved Manageability

The unique housing design of the new KE5 switch cabinet module enables distinct visibility and simplifies mounting, wiring, and maintenance inside switch cabinets and junction boxes.

AS-Interface Product Range

Get to know our full range of AS-Interface products.