Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Base for read/write station U-P3-RX

U-P3-RX
  • Degree of protection IP67
  • With serial interfaces RS 232 and RS 485

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  U-P3-RX

Produktbeskrivelse
Base with serial interfaces RS 232 and RS 485
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS , PELV
Power consumptionmax. 4 W with read/write head IPT*-FP
Galvanic isolation
Operating voltage/interfacefunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Interface
Physical RS-232/RS-485
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400
Cable length≤ 15 m at RS 232
≤ 1200 m at RS-485
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529 with IPT*-FP
Connectionscrew terminals
Interface cable3 conductor, acc. to RS-232 or 2 acc. to RS-485
Supplyup to 3 x 1.5 mm2
Material
Housingdiecast aluminum
Dimensions
Height30 mm
Width80 mm
Length91 mm

Classifications

SystemClasscode
ECLASS 13.027280492
ECLASS 12.027280490
ECLASS 11.027280490
ECLASS 10.0.127280490
ECLASS 9.027280490
ECLASS 8.027280490
ECLASS 5.127279212
ETIM 9.0EC002997
ETIM 8.0EC002997
ETIM 7.0EC002997
ETIM 6.0EC002997
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: U-P3-RX

Function

The base is used in combination with an upper part, the IPT*-FP read/write station. Either an RS 232- or an RS 485-interface is available.

The read/write station is connected to a higher-order control system via the serial interface and receives the commands for writing and/or reading code or data carriers via this interface.

Product Documentation: U-P3-RX

Velg språk:
Brief InstructionsSpråkFiltypeFilstørrelse
Instruction leaflet / BeipackzettelALLPDF390 KB
Commissioning IPT-FP with U-P3-RX at S7-300ENGPDF971 KB
Manuals
Manual IPTx-FP with U-Px-RXENGPDF1748 KB

Design / Simulation: U-P3-RX

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP569 KB
CAD Portal / CAD PortalALLLINK---

Approvals: U-P3-RX

Velg språk:
Declaration of ConformitySertifikatnummerSpråkFiltypeFilstørrelse
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-5411ALLPDF108 KB

Relaterte produkter: U-P3-RX

Matching System Components
LF R/W system, fully assembled as configuration and test stationfa
Visit the RFID Hub