Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Control Stations Division 2, Stainless Steel SR.CS2*

SR.CS2*
  • For use in North America
  • Stainless Steel enclosure
  • Certified for Class I, Division 2 hazardous areas
  • Up to 107 operators per control station
  • 10 enclosure size options
  • Return Flange Sealing provides Drain Channel
  • Customizable configuration of operators, cable entry quantities and cable gland types as per specification
  • Customizable configuration of gland plates, ground bolt and hinges as per specification
  • Option for vertical or horizontal mounting provides high flexibility
  • Up to 4 gland plates
  • Wide range of labels and accessories available

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  SR.CS2*

Produktbeskrivelse
Control Stations Division 2, Stainless Steel
Electrical specifications
Operating voltage250 V AC max.
Operating current5 A max.
Terminal capacity2.5 mm2
Terminal torque0.8 Nm ... 1.2 Nm
Mechanical specifications
Enclosure coverfully detachable , hinged
Cover fixingstainless steel A4 (V4A) hexagonal head screws , see data table
Cover sealsilicone
Degree of protectionType 4X
Cable entrycable glands as per specification
Gland plate on face(s)optional
Material
Enclosure1.5 mm AISI 316L, (1.4404) stainless steel
Gland plateoptional 3 mm or 6 mm AISI 316L (1.4404) stainless steel
Finishbrushed
Masssee data table
valid for empty enclosure, will increase according to integrated components
Dimensionssee data table
Mountingscrews , optional mounting brackets enclosed
GroundingM6 internal/external brass nickel-plated grounding bolt
M6 internal stainless steel grounding bolt welded to lid
M6 internal stainless steel grounding bolt welded to enclosure body
Ambient conditions
Ambient temperature-40 ... 55 °C (-40 ... 131 °F) depending on integrated components
International approvals
ETL approval
ETL certificateIntertek 5003368 , Intertek 5022079
Approved forClass I, Division 2, Groups A, B, C, D
cETLusaccording to UL 508A , UL 121201 , CSA C22.2, No. 213, 286
Ambient temperature-25 ... 40 °C (-13 ... 104 °F) T6
-40 ... 55 °C (-40 ... 131 °F) T5
Conformity
Degree of protectionUL 50 / UL 50E
General information
Ordering informationThis device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Optional accessoriesMounting plate
M6 internal/external stainless steel grounding bolt
gland plate 3 mm AISI 316L (1.4404) stainless steel
gland plate 6 mm AISI 316L (1.4404) stainless steel
M6 internal stainless steel grounding bolt welded to bottom gland plate
quarter-turn key locks stainless steel A4 (V4A)
engraved traffolyte tag label
engraved AISI 316L stainless steel tag label
color in-fill stainless steel tag label
cover padlock facility
Indicators/operating means
Control elementssmall footprint max. 107 see data table
all NC contacts have a direct opening action for emergency stop functions

Classifications

SystemClasscode
ECLASS 13.027180502
ECLASS 12.027180502
ECLASS 11.027180502
ECLASS 10.0.127180502
ECLASS 9.027180502
ECLASS 8.027149144
ECLASS 5.127180502
ETIM 9.0EC002503
ETIM 8.0EC002503
ETIM 7.0EC002503
ETIM 6.0EC002503
ETIM 5.0EC002503
UNSPSC 12.139121314

Details: SR.CS2*

Function

The SR series is a flexible range of control stations for use in Class I, Division 2. The devices are fully customizable and as such will meet the needs of user specifications by being supplied with accessories such as quarter turn locks, mounting brackets or gland plates.

A comprehensive range of operating elements, contact blocks, terminals, entry devices and enclosure accessories are available to ensure each configuration will exactly meet any application requirements.

Enclosures are manufactured from brushed AISI 316L stainless steel and all fixings are manufactured from A4 grade stainless steel as standard to provide excellent tarnish and corrosion resistance.

Your solution can be mounted in portrait or landscape orientation in temperatures ranging from -40°C up to +55 °C. Endless configurations can be confirmed by your local Pepperl+Fuchs office.

Product Documentation: SR.CS2*

Velg språk:
Brief InstructionsSpråkFiltypeFilstørrelse
Brief Instructions - Control Stations SR.CS2* Class I, Division 2ENGPDF286 KB
Instruction leaflet / BeipackzettelALLPDF142 KB

Approvals: SR.CS2*

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
Hazardous Location103993313DAL-003ALLPDF133 KB
SR Series—Stainless Steel Enclosures for Hazardous Areas

The new SR enclosure series made of stainless steel impresses with its modular concept: Discover the range of enclosures that perfectly solves every application—at every level …