Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

EtherNet/IP to Modbus Gateway ICDM-RX/EN1-ST/RJ45-DIN

ICDM-RX/EN1-ST/RJ45-DIN
  • DIN-rail mounting and screw terminal connections
  • EtherNet/IP to Modbus TCP, Modbus TCP to EtherNet/IP, and Modbus to Modbus communications
  • Advanced Modbus gateway and routing capabilities
  • Data Mapping sub-system and a built-in Modbus concentrator
  • Web-based configuration
  • RS-232/422/485 software selectable interfaces
  • NEMA TS2 Certified

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  ICDM-RX/EN1-ST/RJ45-DIN

Produktbeskrivelse
EtherNet/IP to Modbus Gateway 1-port DIN Rail Screw Terminal
General specifications
UL File NumberE360395
MTBF61.4 a
Indicators/operating means
LED indicationsee manual
Electrical specifications
Rated operating voltage5 ... 30 V DC
General informationRedundant power
Nominal voltage24 V DC
Interface
Interface typeSoftware selectable interfaces: RS-232 , RS-422 , RS-485 (2 and 4-wire)
Physical 1 x screw terminal
ProtocolMODBUS RTU
Supported baud rates300 bps to 230Kbps
Interface 1
Interface typeIndustrial Ethernet
Physical 1 x RJ45
ProtocolEtherNet/IP
Additional protocolsARP, BOOTP, DHCP/RARP, HTTP, HTTPS, SSH, SSL/TLS, ICMP, RFC 1006 (ISO over TCP), SNMP (MIB-II), TCP/IP & UDP socket services, Telnet, and TFTP, and supports IP multicast data transmission
Transfer rate10/100 Mbps
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005 , EN 610006-4:2007 , EN 610006-4/A1:2011
RoHSEN IEC 63000:2018
Standard conformity
Degree of protectionNEMA TS2
Electrical safetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
Emitted interferenceEN 61000-6-4, EN 55032, FCC Part 15 Subpart B, ICES-003, AS/NZS CISPR 32
Noise immunityEN 61000-6-2
Ambient conditions
Ambient temperature-40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 95 %
Altitude0 ... 3048 m
Mechanical specifications
Degree of protectionIP20
ConnectionPower Supply: screw terminals
Fieldbus: 1 x RJ45
Inputs/outputs: 9-pin screw terminal block
Material
HousingPolyamide, UL94V-0
Mass113.4g
Dimensions
Height99.1 mm
Width22.9 mm
Length119.3 mm
Construction typeCabinet module
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027242608
ECLASS 12.027242608
ECLASS 11.027242608
ECLASS 10.0.127242608
ECLASS 9.027242608
ECLASS 8.027242608
ECLASS 5.127242608
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICDM-RX/EN1-ST/RJ45-DIN

Function

The ICDM-RX/EN1 gateway enables the connection of serial devices (RS-232 / RS-422 / RS-485) such as barcode scanners, RFID readers and weigh scales to both EtherNet/IP and Modbus networks. It combines an EtherNet/IP interface with a Modbus gateway functionality and a built-in programmable data mapping sub-system, that ties everything together and doubles as a Modbus concentrator. The embedded web pages provide extensive diagnostics, intuitive and flexible configuration options, secure interfaces and numerous maintenance options. The result is a highly flexible gateway that allows full integration of EtherNet/IP controllers into simple or complex Modbus networks. EtherNet/IP controllers such as PLCs, HMIs, SCADAs and OPC servers can communicate to almost any Modbus gateway or client, either locally or remotely.

Informative Literature: ICDM-RX/EN1-ST/RJ45-DIN

Velg språk:
LiteratureSpråkFiltypeFilstørrelse
Product Information - Serial Gateways - DeviceMaster®ENGPDF1227 KB

Product Documentation: ICDM-RX/EN1-ST/RJ45-DIN

Velg språk:
ManualsSpråkFiltypeFilstørrelse
ICDM-RX/EN1 EtherNet/IP to Modbus User ManualENGPDF15866 KB
ICDM-RX/ Hardware Installation and ConfigurationENGPDF12995 KB

Design / Simulation: ICDM-RX/EN1-ST/RJ45-DIN

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP3200 KB

Approvals: ICDM-RX/EN1-ST/RJ45-DIN

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
Canada, USA UL ULE360395ALLLINK---
ODVA Ethernet/IP11976.01ALLPDF38 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4274AALLPDF110 KB
Australia Declaration of ConformityACMA Supplier's declaration of conformityALLPDF302 KB

Software: ICDM-RX/EN1-ST/RJ45-DIN

Velg språk:
Device Description Files/DriversFrigivelsesinfoFiltypeFilstørrelse
EtherNet/IP EDS and firmware files for ICDM-RX/EN1 modules / EtherNet/IP EDS und firmware Dateien für ICDM-RX/EN1 Module2024-09 v1.09ZIP956 KB
Software Tools
PortVision DX v6.02 / PortVision DX v6.022020-08ZIP29584 KB

Relaterte produkter: ICDM-RX/EN1-ST/RJ45-DIN

Accessories
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

Dette gratis PDF-dokumentet sammenligner de forskjellige TCP-baserte kommunikasjonsprotokollene (AMQP, OPC UA, MQTT, REST API) som har funnet veien opp og regnes som muliggjørerne for IIoT og Industry 4.0. Last ned gratis nå!