SMART Transmitter Power Supply/SMART Current Driver
2-channel signal conditioner, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DCpa
SMART Transmitter Power Supply/SMART Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DCpa
SMART Transmitter Power Supply/SMART Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DCpa
SMART Transmitter Power Supply/SMART Current Driver
2-channel isolated barrier, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DCpa
Pepperl+Fuchs adds the KCD2-SCS* interface modules to its portfolio—the first 2-channel, dual-function AI/AO intrinsic safety barriers in a compact 125 mm housing ... interface module for analog signals Pepperl+Fuchs has expanded its portfolio of K-System isolated barriers for DIN rail mounting (power rail) with the KCD2-SCS* interface module. As the first 2-channel AI/AO intrinsic safety barrier with dual function ...
Pepperl+Fuchs is expanding its portfolio of universal isolated barriers with the HiC2422 intrinsic safety barrier ... for connectivity to a variety of control systems. Equivalent devices are also available in the K-System portfolio, which is a DIN rail-mounted solution. These are the KCD2-SCS-Ex2 as an isolated barrier for intrinsically safe signals and the KCD2-SCS-2 ...
Interface technology from Pepperl+Fuchs offers a wide range of components and solutions for hazardous area applications in process índustries ... . Previously, a separate isolator module was required for the input and output signal. The KCD2-SCS* combines both functions in one device. Find out more about the unique 2-channel devices for analog signals with individual configurability of the channels! View ...
What's New at Pepperl+Fuchs? Our most recent news and events are posted here ... with Only One Device As the first 2-channel intrinsically safe AI/AO intrinsic safety barrier with dual function, the KCD2-SCS* interface module can be used wherever analog input and analog output control signals are required ... Wireless Communication for ...
Pepperl+Fuchs'tan elektrikli patlamaya karşı korumaya yönelik çeşitli bileşenler ve çözümler hakkında en yeni broşürleri ve el ilanlarını indirin ... and Pressurization Solutions Download Now This product line card gives you a comprehensive overview of our different types of purge and pressurization systems. 2-channel SMART Transmitter Power Supplies/Current Drivers KCD2-SCS* Download Now Two ...
With the KCD2-SCD-Ex1ES SMART current driver, Pepperl+Fuchs meets the boundary conditions of functional safety according to SIL 3 without the use of special emergency shutdown valves and safety shut-off valves ... işlevlerine ek olarak kısmi strok testleri için HART sinyalleriyle çalıştırılmasıyla gerçekleştirilir. Bu testler, ortam beslemesini tümüyle kapatmadan ve yedek donanım olmadan işlev denetim testi yapılmasına olanak tanır. Örneğin, KCD2-SCD-Ex1.ES SMART akım ...
Basınç vericisinin verici güç kaynağı ile birlikte kullanılması, yağlama döngülerinde yağ basıncını sürekli olarak izlemek için idealdir ... iletilmesine olanak tanır. KCD2-STC-Ex1.ES modülleri genellikle bu uygulama için kullanılır. IEC/EN 61508 uyarınca SIL 3 uyumlu uygulamalara uygundur. Ölçülen sinyal, acil durum kapatma sisteminde (ESD) güvenlik kontrol cihazına iletilir. Burada sinyal sürekli ...
Visit the "Functional Safety Hub" from Pepperl+Fuchs where you find safety assessed devices for process industry applications and also get access to helpful tools and brochures ... the lubrication cycle. A transmitter power supply unit provides an intrinsically safe power supply and ensures that the data is reliably transmitted. KCD2-STC-Ex1.ES modules are typically used for this application. They are suitable for applications up to SIL 3 ...
1-8/8Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.