Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Tam veri sayfasını PDF olarak indirin:
Ürün Açıklaması |
---|
AS-Interface power supply, data decoupling, 8 A |
Indicators/operating means | ||
---|---|---|
LED Overload | Red LED lights up for overload, flashes for hiccup mode |
|
LED PWR | LED green | |
Electrical specifications | ||
Fusing | 3.15 AT (internal) | |
Capacity factor | 0.7 Capacitive at 400 VAC | |
Rated operating voltage | 195 ... 500 V AC | |
Rated operating current | 1 A at 400 VAC | |
Supply frequency | 47 ... 63 Hz | |
Efficiency | 87 % | |
Nominal voltage | 230/400 VAC | |
Peak inrush current | < 50 A | |
Output | ||
Current limit | approx. 8.5 A | |
Voltage | 31.2 V ±1 % | |
Current | 8 A | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 50083-2:2006 | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Standard conformity | ||
AS-Interface | IEC 62026-2:2006 | |
Noise immunity | EN 61000-6-1:2007, EN 61000-6-2:2005 | |
Standards | Harmonic waves: EN 61000-3-2 Class A Interference suppression: EN 55022, EN 55011 Class B Electrostatic discharge (ESD): IEC 61000-4-2 (8 kV contact discharge, 15 kV air discharge) Electromagnetic fields: IEC 61000-4-3 (EN 61000-4-3; 10 V/m) Burst: IEC 61000-4-4 (4 kV input, 2 kV output/capacitively coupled) Surge: IEC 61000-4-5 (4 kV asymmetrical, 4 kV symmetrical) Conducted interference: IEC 61000-4-6 (10 V, 150 kHz to 80 MHz) |
|
Ambient conditions | ||
Ambient temperature | -10 ... 40 °C (14 ... 104 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Protection class | I, Protective conductor connection necessary | |
Connection | Connection terminals, max. conductor cross-section 0.5 to 2.5 mm2 Stripping length 5 to 6 mm |
|
Mass | approx. 1200 g | |
Dimensions | ||
Height | 141 mm | |
Width | 70 mm | |
Length | 151 mm | |
Mounting | DIN mounting rail |
System | Classcode |
---|---|
ECLASS 13.0 | 27040301 |
ECLASS 12.0 | 27040301 |
ECLASS 11.0 | 27040301 |
ECLASS 10.0.1 | 27040301 |
ECLASS 9.0 | 27040301 |
ECLASS 8.0 | 27040301 |
ECLASS 5.1 | 27040301 |
ETIM 9.0 | EC002540 |
ETIM 8.0 | EC002540 |
ETIM 7.0 | EC002540 |
ETIM 6.0 | EC002540 |
ETIM 5.0 | EC002540 |
UNSPSC 12.1 | 39121004 |
The primarily pulsed power pack has been designed for field bus applications which transmit power and data via one single two-wire cable
(AS-Interface concept). It supplies a fully extended AS-Interface system with a 8 A output current. Sinusoidal current drain from the mains avoids harmonics.
The power factor correction feature ensures that the current and the voltage are almost cophasal to avoid reactive power and provide a cos φ > 0.6 power factor. The power pack makes available electric power. In addition to this, it provides for data isolation towards the power source and balancing of the two output lines (AS-Interface + and AS-Interface -) towards the reference potential of the machine (shield connection). Precise transformer coupling allows the use of unshielded load lines.
Fuses:
The power pack is electronically protected against external short circuits. In case of fault, the internal fusible link separates the power pack from the mains.
CAD | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 100 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Sertifika No. | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|---|
US CA UL | CoC E223176 RptRef E223176-20061107 | ALL | 443 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-6843 | ALL | 108 KB |