Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Tam veri sayfasını PDF olarak indirin:
Ürün Açıklaması |
---|
Radar sensor for distance and velocity measuring up to 25 m measuring range |
General specifications | ||
---|---|---|
Measuring technology | FMCW | |
Measured variable | distance velocity |
|
Measuring range | ||
Distance | 0.5 ... 25 m | |
Velocity | 0.1 ... 80 m/s | |
Dead band | 0 ... 0.5 m | |
Standard target plate | corner reflector 100 mm edge length | |
Working frequency | 122.25 ... 123 GHz | |
Opening angle | < 12 ° (see characteristic curve) | |
Transmitter radiated power (EIRP) | < +20 dBm | |
Sampling rate | 1 ... 200 Hz , programmable | |
Nominal ratings | ||
Linearity error | < ± 0.1 % of full-scale value (linearity error incl. temperature drift) | |
Repeat accuracy | 1 mm | |
Resolution | distance 1 mm velocity 0.01 m/s |
|
Time delay before availability | ≤ 400 ms | |
Functional safety related parameters | ||
Performance level (PL) | up to PL c | |
MTTFd | 310 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | up to 60 % , see functional safety manual | |
Indicators/operating means | ||
LED yellow | object within measuring range | |
LED red/green | J1939 status display | |
Electrical specifications | ||
Operating voltage | 9 ... 32 V | |
No-load supply current | ≤ 100 mA | |
Power consumption | typ. 0.4 W , max. 1 W | |
Interface | ||
Interface type | J1939 | |
Process data | status register distance signal quality cycle counter velocity |
|
Transfer rate | 250 kBit/s , 500 kBit/s , programmable | |
Termination | external | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 301489-1 EN 301489-3 EN 305550-1 EN 62368-1 EN 62311 |
|
Approvals and certificates | ||
UL approval | UL Recognized , General purpose , Class 2 power source | |
FCC approval | CFR Title 47, Part 15 FCC ID: IRE-MWL2A |
|
ISED approval | IC ID: 7037A-MWL2A HVIN/PMN: MWL2A |
|
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | fixed cable with plug | |
Degree of protection | IP68 / IP69 | |
Material | ||
Housing | PA-GF35 powder coated metal mounting flange |
|
Radome | PTFE | |
Connector | ||
Number of pins | 6 | |
Connection assembly | Deutsch connector DT04-6P-CE02 Deutsch contact 1060-16-0622 Deutsch wedge W6P |
|
Cable | ||
Cable diameter | 7.25 mm ± 0.2 mm | |
Bending radius | static min. 37.3 mm , dynamic min. 74.7 mm | |
Material | PUR | |
Color | black | |
Number of cores | 5 | |
Core cross section | 0.8 mm2 | |
Length | 352 mm ± 5 mm | |
Mass | 238 g | |
Dimensions | ||
Height | 40 mm | |
Width | 40 mm | |
Length | 83.3 mm | |
Factory settings | ||
Default setting | PGN "Distance and velocity" | |
Sampling rate | 50 Hz | |
Transfer rate | 250 kBit/s |
System | Classcode |
---|---|
ECLASS 13.0 | 27274501 |
ECLASS 12.0 | 27280890 |
ECLASS 11.0 | 27280890 |
ECLASS 10.0.1 | 27280890 |
ECLASS 9.0 | 27280890 |
ECLASS 8.0 | 27280890 |
ECLASS 5.1 | 27270990 |
ETIM 9.0 | EC004807 |
ETIM 8.0 | EC000138 |
ETIM 7.0 | EC000138 |
ETIM 6.0 | EC000138 |
ETIM 5.0 | EC000138 |
UNSPSC 12.1 | 39121528 |
The radar sensor series MWC25M with J1939 interface for medium distances up to 25 m range is optimized for use in industrial applications.Its compact cubic housing of the L2 series is proven in many industrial areas due to its high robustness.
Via Parameter Group Numbers (PGNs), you can directly parameterize the radar sensor optimally for your application. Alternatively, parameterization with extended functionality is also possible using the FDT framework program PACTware and a DTM. This allows you to additionally use various evaluation and filter settings for distance and velocity values.
The radar sensor operates according to the frequency modulated continuous wave (FMCW) method in the ISM band at 122 ... 123 GHz, approved for industrial use. In doing so, it emits a continuous radar signal that is varied over the frequency range of the ISM band. With this method, the sensor is able to reliably detect the distance and velocity of static and moving objects. When measuring velocity, the radar sensor detects the velocity of an object in the radial direction only, without measuring tangential velocities or velocity parts.
Brief Instructions | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 192 KB | |
Commissioning instructions of the MWC25M-L2M-B20 series via PACTwareDC | ENG | 701 KB | |
Safety and Security Documentation | |||
Functional Safety Manual | ENG | 2167 KB |
CAD | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1640 KB |
Certificates | Sertifika No. | Dil | Dosya Tipi | Dosya Boyutu |
---|---|---|---|---|
Canada USA UL | E87056, Vol. 5, Sec. 10 | ALL | 590 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-7782 | ALL | 56 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitätserklärung (P+F) | DOC-7783 | ALL | 53 KB | |
FCC Suppliers Declaration of Conformity / FCC-Konformitätserklärung des Lieferanten | DOC-7784 | ALL | 125 KB |
Device Description Files/Drivers | Sürüm Bilgileri | Dosya Tipi | Dosya Boyutu |
---|---|---|---|
DBC file for MWC25M-L2M-B20* / DBC-Datei für MWC25M-L2M-B20* | ZIP | --- | |
DTM for MWC25M-L2M-B20* / DTM für MWC25M-L2M-B20* | V0.1.0.3 / 2024-09-01 | ZIP | 4048 KB |
J1939 Communication DTM / J1939 Communication DTM | V0.1.0.3 / 2024-10-08 | ZIP | 10716 KB |
Software Tools | |||
CAN Parameterization Tool / CAN Parametriertool | V1.00.003 / 2024-10-07 | ZIP | 226530 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|