选择您所在的国家/地区

转至全球网站

SR.CS2* Control Stations Division 2, Stainless Steel

主要优势一览

  • For use in North America
  • Stainless Steel enclosure
  • Certified for Class I, Division 2 hazardous areas
  • Up to 107 operators per control station
  • 10 enclosure size options
  • Return Flange Sealing provides Drain Channel
  • Customizable configuration of operators, cable entry quantities and cable gland types as per specification
  • Customizable configuration of gland plates, ground bolt and hinges as per specification
  • Option for vertical or horizontal mounting provides high flexibility
  • Up to 4 gland plates
  • Wide range of labels and accessories available

显示详情

Product Compliance: USA - cETLus Intertek
注意

在转换前以倍加福有限公司或倍加福股份公司名义发布的所有产品文档(如证书、符合性声明等)也适用于倍加福欧洲公司。

DE
  • DE
  • EN

SR.CS2* 技术数据

Control Stations Division 2, Stainless Steel
Operating voltage250 V AC max.
Operating current5 A max.
Terminal capacity2.5 mm2
Terminal torque0.8 Nm ... 1.2 Nm
Enclosure coverfully detachable , hinged
Cover fixingstainless steel A4 (V4A) hexagonal head screws , see data table
Cover sealsilicone
Degree of protectionType 4X
Cable entrycable glands as per specification
Gland plate on face(s)optional
Material
Enclosure1.5 mm AISI 316L, (1.4404) stainless steel
Gland plateoptional 3 mm or 6 mm AISI 316L (1.4404) stainless steel
Finishbrushed
Masssee data table
valid for empty enclosure, will increase according to integrated components
Dimensionssee data table
Mountingscrews , optional mounting brackets enclosed
GroundingM6 internal/external brass nickel-plated grounding bolt
M6 internal stainless steel grounding bolt welded to lid
M6 internal stainless steel grounding bolt welded to enclosure body
Ambient temperature-40 ... 55 °C (-40 ... 131 °F) depending on integrated components
ETL approval
ETL certificateIntertek 5003368 , Intertek 5022079
Approved forClass I, Division 2, Groups A, B, C, D
cETLusaccording to UL 508A , UL 121201 , CSA C22.2, No. 213, 286
Ambient temperature-25 ... 40 °C (-13 ... 104 °F) T6
-40 ... 55 °C (-40 ... 131 °F) T5
Degree of protectionUL 50 / UL 50E
Ordering informationThis device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Optional accessoriesMounting plate
M6 internal/external stainless steel grounding bolt
gland plate 3 mm AISI 316L (1.4404) stainless steel
gland plate 6 mm AISI 316L (1.4404) stainless steel
M6 internal stainless steel grounding bolt welded to bottom gland plate
quarter-turn key locks stainless steel A4 (V4A)
engraved traffolyte tag label
engraved AISI 316L stainless steel tag label
color in-fill stainless steel tag label
cover padlock facility
Control elementssmall footprint max. 107 see data table
all NC contacts have a direct opening action for emergency stop functions
一般说明