SK-PC-D2-UU1-10-HS Div. 2 / Zone 2 Ex-rated barrier

主要优势一览

  • 1- or 2-channel Division 2 non-incendive barrier
  • Div 2/Zone 2 mountable
  • USB or PS2 interface for Ex-rated keyboard or mouse
Approval
Product Compliance: Europe – CE
Product Compliance: USA - cULus
注意

在转换前以倍加福有限公司或倍加福股份公司名义发布的所有产品文档(如证书、符合性声明等)也适用于倍加福欧洲公司。

DE
  • DE
  • EN

SK-PC-D2-UU1-10-HS 技术数据

Div. 2 / Zone 2 Ex-rated barrier
Rated voltageUr9 ... 30 VDC (Um = 30 V SELV)
Input current120 mA nominal
500 mA max
LED ONpower - keyboard
power - Mouse
Interface typeUSB 1.1 or PS2
Output current89 mA
Output voltage4.8 VDC
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) #224258
RoHS
Directive 2011/65/EU (RoHS)EN 50581:2012-09
Degree of protectionIEC 60529
Protection against electrical shockIEC 61140
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Relative humidity0 ... 95% (noncondensing)
Vibration resistance5 G, 58 ... 150 Hz
Impact resistance15 g, 11 ms
Connection typeTerminal Block
Degree of protectionIP20
ConnectionSupply: terminals 13+, 14-
Input: terminals 9+, 10-; 11+, 12-
Output: terminals 1+, 2+, 3-, 4-; 5+, 6+, 7-, 8- (field terminal)
Ground: terminals 15, 16
Mass120 g
Dimensions99 mm x 85 mm x 22.5 mm
Cable lengthMax. 4.6 m (15'): barrier to keyboard/mouse
Max. 4.6 m (15'): host pc to keyboard/mouse
Max. 6.1 m (20'): total length, host PC to keyboard/mouse
EU-type examination certificateDEMKO 14ATEX1269806X
MarkingEx-Hexagon II 3 G Ex nA [ic] IIC T6 Gc
[exsign] II 3 G Ex nA [ic IIIB] IIC T6 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
UL approvalcULus (E106378)
Control drawing116-0337
Approved forMountable in
Class I, Division 2, Groups A, B, C, D
Providing non-incendive field wiring at field terminals to
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
Class III, Division 2
Temperature Class T6
Mountable in
Class I, Zone 2
Providing intrinsic safety wiring at field terminals for
Class I, Zone 2, Group IIC and Group IIIB hazardous locations
USL:
Class I, Zone 2 AEx nA [ic] IIC T6 Gc
Class I, Zone 2 AEx nA [ic IIIB] IIC T6 Gc
CNL:
Class I, Zone 2, Ex nA [ic] IIC T6 Gc X
Class I, Zone 2, Ex nA [ic IIIB] IIC T6 Gc X
IECEx approvalIECEx UL 14.0017X
Approved forEx nA [ic] IIC T6 Gc
Ex nA [ic IIIB] IIC T6 Gc
StandardsIEC 60079-0:2011 (6th edition)
IEC 60079-11:2011 (6th edition)
IEC 60079-15:2010 (4th edition)