Your technical, product, or application questions answered in one business day* by our team of experts.
! Please fill in all fields before submitting your question. Pepperl+Fuchs values your privacy. Please read our privacy policy.
* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
PXV100AQ-F200-B28-V1D
Product Description
Read head for incident light positioning system
General specifications
Passage speed
≤ 8 m/s
Measuring length
max. 100000 m
Light type
Integrated LED lightning (red/blue)
Read distance
100 mm
Depth of focus
± 30 mm
Field of view
typ. 120 mm x 80 mm
Ambient light limit
30000 Lux
Accuracy
Non safety-related X
± 0.2 mm
Safety-related X
See the original instructions
Nominal ratings
Camera
Type
CMOS , Global shutter
Processor
Clock pulse frequency
600 MHz
Speed of computation
4800 MIPS
Functional safety related parameters
Safety Integrity Level (SIL)
SIL 3
Performance level (PL)
PL e
Category
Cat. 4
Reaction time
165 ms
MTTF
41 a
MTTFd
104.74 a
Mission Time (TM)
20 a
PFH
1.09 E-8 typ.
Indicators/operating means
LED indication
7 LEDs (communication, status messages)
Electrical specifications
Operating voltage
20 ... 30 V DC , PELV
No-load supply current
max. 300 mA
Power consumption
6 W
Interface
Interface type
100 BASE-TX
Protocol
PROFINET IO Real-Time (RT) Conformance class B
Transfer rate
100 MBit/s
Conformity
Fieldbus standard
PROFIsafe in accordance with IEC 61784-3-3; profile 2.4
Functional safety
EN ISO 13849-1:2015 ; EN 61508:2010 part 1-7 ; EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Shock resistance
EN 60068-2-27:2009
Vibration resistance
EN 60068-2-6:2008
Emitted interference
EN 61000-6-4:2007+A1:2011
Noise immunity
EN 61000-6-7:2015
Photobiological safety
Risk group 2 according to IEC 62471
Approvals and certificates
CE conformity
CE
UL approval
cULus Listed, Class 2 Power Source, Type 1 enclosure
CCC approval
CCC approval / marking not required for products rated ≤36 V
TÜV approval
TÜV Rheinland 01/205/5669.01/20
Ambient conditions
Operating temperature
0 ... 45 °C (32 ... 113 °F) , -20 ... 45 °C (-4 ... 113 °F) (noncondensing; prevent icing on the lens!)
DataMatrix metal code bars for positioning safePXV and safePGV read heads, High temperature resistance, High mechanical stability, Easily exchangeable, Chemically highly resistant, 2-colored Data Matrix codesfa
Marker head for 25 mm code tape, For 25 mm code tapes, Can be used for PCV80..., PCV100..., and PCV130... readers, Includes 2 x edding® 3000 permanent markersfa
Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.