* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
S1SD-2PF
Supply
Connection
Power Bus or terminals 1-, 2+; 7+, 8-
Rated voltage
16.8 ... 31.2 V DC
Fusing
4 AT with back-up fuse
Power dissipation
0.8 W
Output
Connection
Power Bus
Output current
max. 3 A
Output voltage
24 V DC
Indicators/settings
Labeling
space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU
EN 61326-1:2013 (industrial locations)
Conformity
Degree of protection
IEC 60529:2001
Ambient conditions
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F)
Storage temperature
-40 ... 85 °C (-40 ... 185 °F)
Damaging gas
designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protection
IP20
Connection
screw terminals
Core cross section
0.5 ... 2.5 mm2 (20 ... 14 AWG)
Mass
approx. 70 g
Dimensions
6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height
97 mm
Width
6.2 mm
Depth
107 mm
Mounting
on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
Certificate
DEMKO 16 ATEX 1750X
Marking
II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EU
EN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
UL approval
E106378
IECEx approval
IECEx certificate
IECEx UL 16.0116X
IECEx marking
Ex nA IIC T4 Gc
General information
Supplementary information
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Classifications
System
Classcode
ECLASS 13.0
27210129
ECLASS 12.0
27210129
ECLASS 11.0
27210129
ECLASS 10.0.1
27210129
ECLASS 9.0
27210129
ECLASS 8.0
27210190
ECLASS 5.1
27210107
ETIM 9.0
EC002919
ETIM 8.0
EC002919
ETIM 7.0
EC002919
ETIM 6.0
EC002919
ETIM 5.0
EC001485
UNSPSC 12.1
32101514
Details:
S1SD-2PF
Function
The power feed module interfaces 24 V DC power to the Power Bus at a maximum current of 3 A.
Depending on the power consumption up to 75 devices can be supplied via the power feed module.
The device displays the status of the power by a green LED. The device displays a reverse polarity by a red LED.
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 Vpa
1-channel signal conditioner, 24 V DC supply, Input bipolar current and voltage sources, Input 2-wire and 3-wire transmitters, Relay contact output, Restart inhibit, One-shot function, Configurable by DIP switches and software, Connection via screw terminals, Number of channels: 1-channel, Restart inhibit, Time function, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current sourcepa
Netlist price. Your individual price will be calculated during checkout.
In stock
Item 'S1SD-1AI-1C.H' added to cart!
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire SMART transmitters and current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, HART communication, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa
1-channel signal conditioner, 24 V DC supply, Input current and voltage sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 V, Configuration: via DIP switchespa
1-channel signal conditioner, 24 V DC supply, Input bipolar current and voltage sources, Output bipolar current and voltage sources, Accuracy 0.1 %, Configurable via DIP switches and potentiometer, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/2 ... 10 mA, Signal [2]: 0/4 ... 20 mA, Signal [5]: 0/1 ... 5 V, Signal [7]: 0/2 ... 10 V, Line fault detection, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x -10 ... 10 mApa
1-channel signal conditioner, 24 V DC supply, Input bipolar millivolt sources, Output bipolar current and voltage sources, Accuracy 0.1 %, Configurable via DIP switches and potentiometer, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x -10 ... 10 mA, Signal [3]: 1 x -20 ... 20 mA, Signal [4]: 1 x 0/1 ... 5 V, Signal [5]: 1 x 0/2 ... 10 V, Signal [6]: 1 x -5 ... 5 Vpa
Netlist price. Your individual price will be calculated during checkout.
In stock
Item 'S1SD-1AI-2C' added to cart!
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA ... 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, splitter function (1 input and several outputs)pa
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Input current and voltage sources, Dual output 0/4 mA ... 20 mA, 0/1 V ... 5 V or 0/2 V ... 10 V, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 2 x 0/4 ... 20 mApa
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Time function, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensor, Field device [5]: S0 sensor, Field device [6]: NPN sensorpa
Netlist price. Your individual price will be calculated during checkout.
In stock
Item 'S1SD-1TI-1U' added to cart!
1-channel signal conditioner, 24 V DC supply, Thermocouple, RTD, potentiometer or mV input, Input for PTC thermistor, Current and voltage output, Line fault (LFD) and sensor burnout detection, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometer, Field device [2]: Thermocouplepa
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors, Input frequency 10 mHz ... 50 kHz, Relay contact output, Start-up override and restart inhibit, Configurable by DIP switches and software, Connection via screw terminals, Number of channels: 1-channel, Restart inhibit, Start-up override, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensorpa
1-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa
2-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 2-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 2 x 0/4 ... 20 mApa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa