Línea de servicio de Sensores Industriales
+52 55 5636-0970
+52 55 5636-0975
Atención al cliente para protección contra explosiones
+52 55 5636-0970
+52 55 5636-0975

IO-Link printed circuit board module ICA-8DIO-CB10-IO

ICA-8DIO-CB10-IO
  • Outputs short-circuit and overload proof
  • Connection via lead
  • IO-Link interface
  • Ultra-compact enclosure
  • 8 digital inputs/outputs can be configured

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  ICA-8DIO-CB10-IO

Descripción del producto
I/O hub with IO-Link interface
Indicators/operating means
LED PWRLED green: flashing with short break (1 Hz) - IO-Link mode
LED OLoverload of sensor power supply; LED red
LED IOSwitching status/overload (input/output); 8 LED yellow/red
yellow: input/output active
red: output overload
Electrical specifications
Operating voltage18 ... 30 V DC, PELV
No-load supply currentmax. 25 mA
Operating currentmax. 2 A
Protection classIII
Interface
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Process dataInputs 2 Byte
- Input signals 8 Bit
- diagnosis signals 4 Bit
Outputs 2 Byte
- Output signals 8 Bit
- Special functions 8 Bit
Vendor ID1 (0x0001)
Device ID984577 (0x0F0601)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time1 ms
SIO mode supportno
Compatible master port typeClass A , Class B
Input
Number/Type8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8)
Supplyfrom IO-Link
Voltage18 ... 30 V
Current loading capacity400 mA , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 1 according to IEC 61131-2
Output
Number/Type8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof
Supplyfrom IO-Link
Voltage≥ (UB - 1.5 V)
Current200 mA per output
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
EN 55011:2016
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 61131-9:2013
InputEN 61131-2:2007
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006
Approvals and certificates
UL approvalProtection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs.
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 5000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
Vibration resistance0.35 mm / 5 g 5 ... 500 Hz
Pollution degree2
Mechanical specifications
Degree of protectionIP20 according to EN 60529
Connection200 mm, PVC cable 0.5 mm2
Material
HousingPolyamide hot-melt adhesive
Mass33 g
Dimensions
Height10 mm
Width36 mm
Length39.5 mm
NoteThis device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired.

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: ICA-8DIO-CB10-IO

Product Documentation: ICA-8DIO-CB10-IO

Seleccionar idioma:
Parameter InformationIdiomaTipo de archivoTamaño
IO-Link Parameter Datasheet ICA-8DIO-CB10-IOENGPDF458 KB

Design / Simulation: ICA-8DIO-CB10-IO

Seleccionar idioma:
CADIdiomaTipo de archivoTamaño
CAD 3-D / CAD 3-DALLSTP194 KB

Approvals: ICA-8DIO-CB10-IO

Seleccionar idioma:
CertificatesNúmero de CertificadoIdiomaTipo de archivoTamaño
IO-Link Manufacturer DeclarationCERT-6654ALLPDF273 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-5866ALLPDF115 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5867ALLPDF113 KB

Software: ICA-8DIO-CB10-IO

Seleccionar idioma:
Device Description Files/DriversLiberar InfoTipo de archivoTamaño
IODD for ICA-8DIO-CB10-IO / IODD für ICA-8DIO-CB10-IOV1.02.000 / 2022-09-07ZIP233 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Productos asociados: ICA-8DIO-CB10-IO

Accessory of
PROFINET and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
EtherNet/IP IO-Link master with 8 inputs/outputsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
Ethernet IO-Link module with eight IO-Link portsfa
Ethernet IO-Link module with 4x Class A and 4x Class B IO-Link portsfa
PROFINET IO IO-Link master with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
EtherNet/IP and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa
Ethernet IO-Link module with 8 inputs/outputsfa
Firmware variant from ICE3-8IOL-G65L-V1D with Modbus enabled by defaultfa
Kit de inicio de IIoT

Conecte sus sensores de la fábrica a la nube e inicie la transformación digital con los nuevos kits de inicio de IIoT.