Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Last ned komplett datablad som PDF:
Datablad utdrag: Tekniske data for
MLV41-8-HV-60-IR/110/124/167
Produktbeskrivelse |
Robust diffuse mode sensor for monitoring web breaks, compact housing design, foreground and background suppression, 60 mm detection range, infrared light, push-pull output, stability alarm output, M12 plug |
General specifications |
Foreground suppression | 0 ... 15 mm |
Detection range | on black (6 %): 20 ... 60 mm fixed setting |
Detection range min. | 20 ... 60 mm |
Detection range max. | 16 ... 70 mm |
Background suppression | starts from 70 mm |
Light source | IRED |
Light type | modulated infrared light , 880 nm |
Polarization filter | no |
Black-white difference (6 %/90 %) | < 1 % at 60 mm |
Diameter of the light spot | max. 6 mm at a distance of 70 mm |
Opening angle | approx. 4 ° |
Ambient light limit | 50000 Lux |
Functional safety related parameters |
MTTFd | 1260 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green, statically lit Power on, short-circuit or low voltage : pulsing (1 Hz). Pollution : flashing (1 Hz) |
Function indicator | 2 LEDs yellow ON: object inside the scanning range OFF: object outside the scanning range |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | 10 % |
No-load supply current | max. 25 mA |
Input |
Test input | emitter deactivation at +UB |
Output |
Stability alarm output | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected |
Signal output | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA |
Voltage drop | ≤ 2.5 V DC |
Switching frequency | 250 Hz |
Response time | 2 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
Protection class | II, rated voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 |
UL approval | cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure) |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | 0 ... 70 °C (32 ... 158 °F) |
Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 5-pin, M12 x 1 connector |
Material | |
| Housing | Aluminum , Delta-Seal coated |
| Optical face | glass pane |
| Connector | metal |
Mass | 50 g |
Dimensions | |
| Height | 56.5 mm |
| Width | 31 mm |
| Depth | 13.6 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270903 |
ECLASS 10.0.1 | 27270903 |
ECLASS 9.0 | 27270903 |
ECLASS 8.0 | 27270903 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC001821 |
ETIM 8.0 | EC001821 |
ETIM 7.0 | EC001821 |
ETIM 6.0 | EC001821 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Details:
MLV41-8-HV-60-IR/110/124/167
Product Documentation:
MLV41-8-HV-60-IR/110/124/167
Design / Simulation:
MLV41-8-HV-60-IR/110/124/167
Approvals:
MLV41-8-HV-60-IR/110/124/167
Relaterte produkter:
MLV41-8-HV-60-IR/110/124/167
Accessories |
|
|
|
Mounting bracketfa |
|
|
|
|
Mounting bracketfa |
|
|
|
|
Mounting bracket fa |
|
|
|
|
Mounting bracket for Sensors series MLV41 for M12 rod mountingfa |
|