Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Convergent beam sensor ML100-8-HGU-100-RT/102/115/162

ML100-8-HGU-100-RT/102/115/162
  • Miniature design
  • Diffuse mode sensor with long, narrow light spot
  • Easy to use
  • Very bright, highly visible light spot
  • Full metal thread mounting

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  ML100-8-HGU-100-RT/102/115/162

Produktbeskrivelse
Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, fixed cable
General specifications
Detection range10 ... 100 mm
Adjustment range30 ... 100 mm
Reference targetstandard black, 100 mm x 100 mm
Light sourceLED
Light typemodulated visible red light
Polarization filterno
Diameter of the light spotapprox. 6 mm x 60 mm at 100 mm
Opening angleEmitter: 3.5 ° vertical ; 30 ° horizontal
Optical facefrontal
Ambient light limitEN 60947-5-2:2007+A1:2012
Functional safety related parameters
MTTFd860 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: power on
Function indicatorLED yellow: lights when object is detected
Control elementsSensing range adjuster
Control elementsLight-on/dark-on changeover switch
Electrical specifications
Operating voltage10 ... 30 V DC
Ripplemax. 10 %
No-load supply current< 20 mA
Output
Switching typeThe switching type of the sensor is adjustable. The default setting is: light-on
Signal output1 NPN output, short-circuit protected, reverse polarity protected, open collector
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA , resistive load
Voltage drop≤ 1.5 V DC
Switching frequency500 Hz
Response time1 ms
Conformity
Product standardEN 60947-5-2
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP67
Connection2 m fixed cable
Material
HousingPC (Polycarbonate)
Optical facePMMA
Massapprox. 50 g
Tightening torque, fastening screws0.6 Nm
Dimensions
Height31 mm
Width11 mm
Depth20 mm
Cable length2 m

Classifications

SystemClasscode
ECLASS 13.027270903
ECLASS 12.027270903
ECLASS 11.027270903
ECLASS 10.0.127270903
ECLASS 9.027270903
ECLASS 8.027270903
ECLASS 5.127270903
ETIM 9.0EC001821
ETIM 8.0EC001821
ETIM 7.0EC001821
ETIM 6.0EC001821
ETIM 5.0EC001821
UNSPSC 12.139121528

Details: ML100-8-HGU-100-RT/102/115/162

Function

The optical sensors of this series are suitable for both standard and demanding applications.

The series features a miniature housing design, two M3 metal-threaded mounting holes and a highly visible LED status indicator.

Each device is equipped with a sensitivity adjuster and a light-on/dark-on changeover switch for increased flexibility.

A wide variety of versions are available in both infrared light and red light with PowerBeam for easy alignment.

Special versions with BlueBeam are suitable for challenging applications like those in the solar and battery industries.

Informative Literature: ML100-8-HGU-100-RT/102/115/162

Velg språk:
LiteratureSpråkFiltypeFilstørrelse
Application Report - Reliable Detection in PCB ProductionENGPDF186 KB

Product Documentation: ML100-8-HGU-100-RT/102/115/162

Velg språk:
Brief InstructionsSpråkFiltypeFilstørrelse
Instruction leaflet / BeipackzettelALLPDF453 KB

Design / Simulation: ML100-8-HGU-100-RT/102/115/162

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP1021 KB

Approvals: ML100-8-HGU-100-RT/102/115/162

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
USA UL E87056UL-US-2015966-0 / UL-CA-2012696-0ALLPDF550 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F)DOC-0435FALLPDF311 KB
UK Declaration of Conformity (P+F) / UK-Konformitätserklärung (P+F)DOC-5267ALLPDF230 KB

Relaterte produkter: ML100-8-HGU-100-RT/102/115/162

Accessories
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Mounting aid for ML100 series, Mounting bracketfa
Mounting aid for ML100 series, Mounting bracketfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Mounting aid for ML100 series, Mounting bracketfa
Mounting aid for ML100 series, Mounting bracketfa
Mounting aid for ML100 seriesfa
Mounting aid for ML100 seriesfa
Mounting bracket , Simple installation, Robust construction, Secure mounting, Mounting head and foot may be independently rotated through 360°fa
Fotoceller i R10x- og R20x-serien

For første gang er en konsekvent løsningsserie med fotoelektriske funksjonsprinsipper og innovative teknologier tilgjengelig i identiske kapslinger. Brukere drar fordel av et uniformt driftskonsept over hele porteføljen. Oppdag seriene R100, R101, R103, R200 og R201 ...

ML100-fotocelle

Uansett om det er glass, silisiumskiver eller kretskort: Fotocellene i ML100-serien er spesiallaget for å oppfylle kravene til komplekse registreringsoppgaver. Lær mer om porteføljen ...