IO-Link converter ICA-AI-I/U-IO-V1

ICA-AI-I/U-IO-V1
  • IO-Link interface
  • IP67
  • Analog input can be parameterized (current/voltage)
  • Current input can be parameterized as 0 … 20 mA/4 … 20 mA
  • Voltage input can be parameterized as -10 … 10 V/0 … 10 V

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  ICA-AI-I/U-IO-V1

Produktbeskrivelse
IO-Link converter with analog input (current/voltage)
General specifications
UL File NumberE223772
Functional safety related parameters
MTTFd246 a
Indicators/operating means
LED 1Device status, diagnostics
LED 2IO-Link status
Electrical specifications
Rated operating voltage18 ... 30 V
Nominal voltage24 V DC
Nominal current230 mA
Current consumptiontyp. 30 mA
Surge protectionCategory II
Interface
Interface typeIO-Link
IO-Link revision1.1
Device ID0x0F0501 (984321)
Transfer rateCOM2 (38.4 kBit/s)
Min. cycle time2.3 ms
Process data width16 bits / 2 bytes
SIO mode supportno
Compatible master port typeA, B
Input
Number/Type1 analog input for sensors with analog output
Sensor supply17 … 29.8 V DC
≤ 200 mA
Measuring rangeCurrent input or voltage input, configurable:
0 mA…20 mA
4 mA…20 mA
0 V…10 V
-10 V…10 V
Accuracy0.1 % FS at 25 °C
ResolutionADC: 24 Bit
Process data: 16 bit
Sampling ratemax. 200 Hz
Input filterAverage determination of process data, parameterizable
Temperature influence45 ppm/°K
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardIEC 61131-9 / IO-Link V1.1
Emitted interferenceEN 61000-6-4
Noise immunityEN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6
Shock resistanceEN 60068, Part 2-6, Part 2-27
Ambient conditions
Ambient temperature-30 ... 70 °C (-22 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 85 %
Climatic conditionsClimatic class 3K3
Altitude0 ... 2000 m
Shock and impact resistance50 g, 11 ms, all axes
Pollution degree3
Mechanical specifications
Degree of protectionIP67
ConnectionIO-Link M12, A-coded
Input M12, A-coded
Material
ContactsZinc, CuNi plated
HousingPlastic PC + PBT
Mass44 g
Dimensions
Height32.3 mm
Width15 mm
Length77.2 mm
Construction typeField housing

Classifications

SystemClasscode
ECLASS 13.027242601
ECLASS 12.027242601
ECLASS 11.027242601
ECLASS 10.0.127242601
ECLASS 9.027242601
ECLASS 8.027242601
ECLASS 5.127242601
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICA-AI-I/U-IO-V1

Product Documentation: ICA-AI-I/U-IO-V1

Velg språk:
ManualsSpråkFiltypeFilstørrelse
Manual ICA-AI-I/U-IO-V1 and ICA-AO-I/U-IO-V1ENGPDF1460 KB
Parameter Information
Parameterdatenblatt / Parameter DatasheetENGPDF369 KB

Design / Simulation: ICA-AI-I/U-IO-V1

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP1522 KB
CAD Portal / CAD PortalALLLINK---

Approvals: ICA-AI-I/U-IO-V1

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
IO-Link Manufacturer DeclarationCERT-6084AALLPDF174 KB
US CA ULCoC E223772 RepRef E223772-20171113ALLPDF441 KB
Declaration of Conformity
EU-Declaration of conformityTDOC-5028BENGENGPDF196 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6905ALLPDF106 KB

Software: ICA-AI-I/U-IO-V1

Velg språk:
Device Description Files/DriversFrigivelsesinfoFiltypeFilstørrelse
IODD for ICA-AI-I/U-IO / IODD für ICA-AI-I/U-IOV1.01.000 / 2023-12-14ZIP156 KB

Relaterte produkter: ICA-AI-I/U-IO-V1

Accessory of

Ethernet IO-Link module with eight IO-Link portsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa

EtherNet/IP IO-Link master with 8 inputs/outputsfa
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with analog current output, Series: Performance Line, Measured variable: Vibration acceleration, Vibration acceleration: 0 ... 10 g rms, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity
Temperature, Output type: analog output, current
output of the vibration variable, Output type: analog output, current
output of the temperaturefa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on requestfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
Vibration sensor with analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity
Temperature, Output type: analog output, current
output of the vibration variable, Output type: analog output, current
output of the temperaturefa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
PROFINET and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
Ethernet IO-Link module with 4x Class A and 4x Class B IO-Link portsfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration acceleration, Vibration acceleration: 0 ... 10 g rms, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on requestfa
Firmware variant from ICE3-8IOL-G65L-V1D with Modbus enabled by defaultfa
EtherNet/IP and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
Accessories
torque screwdriver (0.6 Nm)fa
plug-in cap M12fa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
IIoT Starter Kit

Connect your factory floor sensors to the cloud and start your digital transformation with the new IIoT starter kits.