Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

RFID read/write device IQT1-FP-IO-V1

IQT1-FP-IO-V1
  • Operating frequency 13.56 MHz
  • IO-Link interface
  • Conforms to ISO 15693
  • Suitable for FRAM transponder
  • LEDs as function indicators
  • Connection via V1 (M12 x 1) plug connection
  • Degree of protection IP67
  • For connection to IO-Link master

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  IQT1-FP-IO-V1

Opis produktu
HF RFID read/write device with IO-Link in accordance with ISO 15693
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 130 mm
Write distance0 ... 130 mm
Widthmax. 100 mm
MTBF140 a (Operation at +40 °C)
Indicators/operating means
LED red/greenGreen: power on
Flashing green: IO-Link communication
Flashing red/green: IO-Link communication interrupted
LED blue/yellowBlue: Write/read attempt performed
Yellow: Read/write tag detected
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 70 mA (at 24 V DC)
Power consumption≤ 2 W
Interface
Interface typeIO-Link
IO-Link revision1.1
Process dataInput 32 Byte
Output 32 Byte
Vendor ID1 (0x0001)
Device ID4194561 (0x400101)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time4 ms
SIO mode supportno
Compatible master port typeClass A
Class B
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
Communication interfaceIEC 61131-9 / IO-Link V1.1.2
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
UL approvalE87056
cULus Listed, Class 2 Power Source, Type 1 enclosure
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
MIC approvalAC-21098
Radio approvalUSA: FCC IREIQT1FPIO
Canada: 7037A-IQT1FPIO
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPBT
Basediecast aluminum
Encapsulation compoundCY 221/HY 2966
Installation
Distance between two heads≥ 150 mm
Massapprox. 380 g
Dimensions
Height40 mm
Width80 mm
Length108.5 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IQT1-FP-IO-V1

Informative Literature: IQT1-FP-IO-V1

Language Selection:
LiteratureJęzykTyp plikuRozmiar pliku
Application Report - RFID Systems in Industrial Metal StampingENGPDF1773 KB

Product Documentation: IQT1-FP-IO-V1

Language Selection:
Product informationJęzykTyp plikuRozmiar pliku
Installation and user instructions for offline parameterization of IO-Link sensorsENGPDF1788 KB
Manuals
ManualENGPDF2227 KB

Design / Simulation: IQT1-FP-IO-V1

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DALLSTP1576 KB
CAD Portal / CAD PortalALLLINK---

Approvals: IQT1-FP-IO-V1

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
Canada Radio Approval7037A-IQT1FPIOALLPDF1829 KB
Canada, USA ULCoC UL-CA-L87056-31-61115002-0 / UL-US-L87056-11-61115002-0ALLPDF561 KB
IO-Link Manufacturer DeclarationCERT-4469ALLPDF160 KB
Japan Radio ApprovalCERT-6239ALLPDF216 KB
USA FCC ApprovalIREIQT1FPIOALLPDF127 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3819BALLPDF110 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7036ALLPDF108 KB

Software: IQT1-FP-IO-V1

Language Selection:
Device Description Files/DriversInformacja o wersjiTyp plikuRozmiar pliku
IODD for IQT1 series / IODD für IQT1-Serie1.01.000 / 2018-02-22ZIP239 KB
Add-On Instructions for RSLogix/Studio 5000. Reading and writing of Parameters to IQT1 RFID Heads and Easy and Expert mode(Function Blocks) Add-On Instructions to read and write RFID data to a tag. / Inbetriebnahmedatei_a5/2023ZIP31797 KB
Function block "IQT1_EasyMode" and "IO_Link_Device" for RFID head IQT1-...-IO-V1 with ICE3 IO-Link Master on Step 7 Classic / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Device" für RFID-Kopf IQT1-...-IO-V1 mit ICE3 IO-Link Master an Step 7 ClassicZIP8343 KB
Function block "IQT1_EasyMode" and "IO_Link_Device" for RFID head IQT1-...-IO-V1 with ICE3 IO-Link Master on TIA Portal / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Device" für RFID-Kopf IQT1-...-IO-V1 mit ICE3 IO-Link Master an TIA PortalZIP8675 KB
Function block "IQT1_EasyMode" and "IO_Link_Parameter" for RFID head IQT1-...-IO-V1 with EL6224 IO-Link Master on Beckhoff TwinCAT 3 / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Parameter" für den RFID-Kopf IQT1-...-IO-V1 mit EL6224 IO-Link Master an Beckhoff TwinCAT3ZIP21489 KB
Function blocks TIA Portal (S7-1200/1500) for the RFID device IQT1-xx-IO-V1 (IO-Link) when using the Expert Mode / Funktionsbausteine TIA Portal (S7-1200/1500) für das RFID-Gerät IQT1-xx-IO-V1 (IO-Link) bei der Verwendung des Expert ModesV2.1ZIP10718 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Produkty powiązane: IQT1-FP-IO-V1

Accessories

Ethernet IO-Link module with eight IO-Link portsfa

EtherNet/IP IO-Link master with 8 inputs/outputsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable black, UL approvedfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PUR cable black, UL-approved, drag chain suitable, torsion resistantfa