Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Pobierz pełną kartę katalogową w formie pliku PDF:
Opis produktu |
---|
Evaluation unit for the ultrasonic sensor system USi-industry with switching outputs (stand-alone device/secondary device) |
General specifications | ||
---|---|---|
Type | USi-industry evaluation unit | |
Sensing range | 10 ... 2500 mm factory setting: 2000 mm |
|
Adjustment range | 150 ... 2500 mm | |
Dead band | 0 ... 10 mm | |
Object size | typ. ∅ 10 mm | |
Transducer frequency | approx. 103 kHz | |
Response delay | 10 ... 20000 ms factory setting: 150 ms |
|
Sensor cycle time | 10 ... 200 ms factory setting: 50 ms |
|
Resolution | 1 mm | |
Target velocity | axial (max.): typ. 2 m/s (up to 2.5 m/s) | |
Repeat accuracy | ± 0.1 % of full-scale value | |
Temperature influence | automatic or manual temperature compensation available , without temperature compensation: 0.17 %/K |
|
Indicators/operating means | ||
LED green | supply voltage/device status | |
LED yellow | output states | |
Button | Teach-in | |
Electrical specifications | ||
Operating voltage | 9 ... 30 V DC |
|
No-load supply current | ≤ 160 mA | |
Power consumption | < 2.5 W | |
Time delay before availability | ≤ 300 ms | |
Interface | ||
Interface type | USB 2.0 | |
Inputs | ||
Input type | 2 inputs for ultrasonic transducers 1 digital input |
|
Output 1 | ||
Designation | OUT 1.1 | |
Output type | switching output: PNP Normally open/closed (NO/NC) parameterizable |
|
Voltage drop | ≤ 2.5 V | |
Switching frequency | 0.05 Hz ... 100 Hz | |
Off-state current | ≤ 100 µA | |
Switching voltage | max. UB | |
Switching current | 100 mA | |
Output 2 | ||
Designation | OUT 1.2 | |
Output type | switching output: PNP Normally open/closed (NO/NC) parameterizable |
|
Voltage drop | ≤ 2.5 V | |
Switching frequency | 0.05 Hz ... 100 Hz | |
Off-state current | ≤ 100 µA | |
Switching voltage | max. UB | |
Switching current | 100 mA | |
Output 3 | ||
Designation | OUT 2.1 | |
Output type | switching output: PNP Normally open/closed (NO/NC) parameterizable |
|
Voltage drop | ≤ 2.5 V | |
Switching frequency | 0.05 Hz ... 100 Hz | |
Off-state current | ≤ 100 µA | |
Switching voltage | max. UB | |
Switching current | 100 mA | |
Output 4 | ||
Designation | OUT 2.2 | |
Output type | switching output: PNP Normally open/closed (NO/NC) parameterizable |
|
Voltage drop | ≤ 2.5 V | |
Switching frequency | 0.05 Hz ... 100 Hz | |
Off-state current | ≤ 100 µA | |
Switching voltage | max. UB | |
Switching current | 100 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 55011:2016-04 |
|
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug | |
Degree of protection | IP65 | |
Connection | for power supply and outputs: connector plug M12, 8-pin, connection line max. 30 m for ultrasonic transducer: for each socket M8, 3-pin for parameterization: socket Mini USB |
|
Material | ||
Housing | diecast aluminum | |
Mass | 250 g | |
Dimensions | ||
Height | 35 mm | |
Width | 77 mm | |
Length | 98 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
The USi-industry ultrasonic sensor system is used in applications for object detection, area monitoring and distance measurement, for example on machines and systems. It is also used as an assistance system on mobile machines such as robots and driverless transport systems (AGVs) for collision avoidance both indoors and outdoors. The evaluation unit and the ultrasonic transducers to be connected to it are separate units. This enables a high degree of flexibility and a wide range of applications, so that even the smallest installation spaces can be used for ultrasonic sensor technology.
Up to 2 ultrasonic transducers with an elliptical sound field can be connected to the evaluation unit and freely positioned. Each ultrasonic transducer is assigned 2 outputs. The evaluation unit has a total of 4 outputs as well as 1 digital input and 1 synchronization line, all of which can be parameterized individually and independently of each other and integrated into a wide variety of applications. All types of USi-industry evaluation units are delivered as stand-alone devices and are therefore equivalent, regardless of whether they are main devices or secondary devices. Even without an electrical connection, several individual devices can be operated together without interference by means of special parameterization.
The digital input can be defined for one of the following functions, either
to switch off the outputs or
to switch to another parameter set without interruption or
for teaching in a changing environment during operation.
The teach-in button can be used to
teach in the environment of the detection area,
set the switching points,
log the second ultrasonic transducer on or off and
reset the evaluation unit to the factory settings.
Complete parameterization is conveniently carried out using the Device Type Manager (DTM) under PACTware via the integrated USB interface. These parameters define the inputs and outputs, switching points and operating modes, sensor and ultrasound-specific values as well as synchronization options and temperature compensation. as well as synchronization options and temperature compensation.
Literature | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Product Information - Ultrasonic Sensor Systems USi®-industry and USi®-safety | ENG | 1781 KB | |
Application Report | ENG | 347 KB | |
Application Report | ENG | 333 KB |
Manuals | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Manual USi-industry USI*-F264-*-V19 | ENG | 2461 KB |
Certificates | Nr. certyfikatu | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|---|
Canada USA UL Ordinary Location | E87056, Vol.1, Sec.65 | ALL | 285 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-7654 | ALL | 69 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitätserklärung (P+F) | DOC-7655 | ALL | 67 KB |
Device Description Files/Drivers | Informacja o wersji | Typ pliku | Rozmiar pliku |
---|---|---|---|
DTM for USI*-F264-* / DTM für USI*-F264-* | V1.0.0.3 / 2024-10-08 | ZIP | 22284 KB |
Software Tools | |||
PACTware 6.X / PACTware 6.X | 6.1 | ZIP | 335938 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|