Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Ultrasonic sensor UB2000-F54-E4-V15

UB2000-F54-E4-V15
  • Switching output
  • 5 different output functions can be set
  • Program input
  • Synchronization options
  • Deactivation option
  • Temperature compensation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  UB2000-F54-E4-V15

Opis produktu
Single head system
General specifications
Sensing range80 ... 2000 mm
Adjustment range100 ... 2000 mm
Dead band0 ... 80 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 175 kHz
Response delay≤ 150 ms
Indicators/operating means
LED greensolid green: monitoring system
green flashing: program function
LED yellowindication of the switching state
flashing: program function object detected
LED redflashing:
normal mode: error
Program function: no object detected
permanently:
Program mode, object uncertain
Electrical specifications
Operating voltage10 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 55 mA
Input/Output
Synchronization1 synchronous input
0-level: -UB...+1 V
1-level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: 0,1 ... 28 ms
Synchronization frequency
Common mode operationmax. 33 Hz
Multiplex operation≤ 33 / n Hz, n = number of sensors
Input
Input type1 program input,
switching point A1: -UB ... +1 V, switching point A2: +4 V ... +UB
input impedance: > 4.7 kΩ, program pulse: ≥ 1 s
Output
Output type1 switch output E4, NPN, NO/NC
Rated operating current200 mA , short-circuit/overload protected
Voltage drop≤ 3 V
Repeat accuracy≤ 1 % of full-scale value
Switching frequencymax. 3 Hz
Range hysteresis≤ 1 % of the set operating distance
Temperature influence± 1.5 % of full-scale value
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 5-pin
Degree of protectionIP65
Material
HousingABS
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Mass100 g
Dimensions
Height31 mm
Width105 mm
Length25 mm

Classifications

SystemClasscode
ECLASS 13.027272803
ECLASS 12.027272803
ECLASS 11.027272803
ECLASS 10.0.127272803
ECLASS 9.027272803
ECLASS 8.027272803
ECLASS 5.127272803
ETIM 9.0EC001849
ETIM 8.0EC001849
ETIM 7.0EC001849
ETIM 6.0EC001849
ETIM 5.0EC001849
UNSPSC 12.141111960

Details: UB2000-F54-E4-V15

Informative Literature: UB2000-F54-E4-V15

Language Selection:
LiteratureJęzykTyp plikuRozmiar pliku
Application Report - Ultrasonic Technology - Ultrasonic Sensors Regulate Material FeedENGPDF224 KB

Product Documentation: UB2000-F54-E4-V15

Language Selection:
Brief InstructionsJęzykTyp plikuRozmiar pliku
Instruction leaflet / BeipackzettelALLPDF219 KB
Safety and Security Documentation
Instrukcja obsługiPOLPDF148 KB

Design / Simulation: UB2000-F54-E4-V15

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DALLSTP140 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
EPLAN macro EDZ / EPLAN Makro EDZALLEDZ61 KB

Approvals: UB2000-F54-E4-V15

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2595BALLPDF47 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5454ALLPDF40 KB

Produkty powiązane: UB2000-F54-E4-V15

Accessories

Female cordset single-ended M12 straight A-coded, 5-pin, PVC cable greyfa

Female cordset single-ended M12 angled A-coded, 5-pin, PUR cable greyfa
Programming unitfa
System czujników USi-safety

System czujników ultradźwiękowych USi-safety stanowi przełom w zastosowaniach związanych z bezpieczeństwem. Czujniki można stosować zarówno w trudnych warunkach, w zapylonym środowisku, jak i na zewnątrz.

Firma Pepperl+Fuchs oferuje różne dokumenty do pobrania zawierające informacje na temat czujników ultradźwiękowych.