Pobierz pełną kartę katalogową w formie pliku PDF:
Opis produktu |
---|
Wireless ultrasonic sensor with GSM (2G) interface |
General specifications | ||
---|---|---|
Radio network | GSM | |
Measurement interval | 5 min ... 24 h | |
Main sensor | ||
Detection type | ultrasonic | |
Sensing range | 250 ... 4000 mm | |
Dead band | 0 ... 250 mm | |
Resolution | 16 mm (corresponding to 1 LSB) | |
Accuracy | ± 3 % of full-scale value over the entire temperature range | |
Integrated sensor technology | ||
GPS sensor | ||
Accuracy | < 2.5 m CEP at -130 dbm | |
Temperature sensor | ||
Resolution | 0.5 °C | |
Accuracy | ± 2 °C | |
Electrical specifications | ||
Power supply | high capacity lithium battery 3.6 V , 13000 mAh battery lifetime approx. 5 years under Central European environmental conditions (- 25 °C .... + 70 °C) 3 measurements/day, 1 geolocation/day with 1 wireless transmission/day with sufficient network coverage. |
|
Interface 1 | ||
Interface type | Bluetooth 5.0 LE | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 2402 ... 2480 MHz | |
Interface 2 | ||
Interface type | GSM | |
Transmitter radiated power | + 20 dBm | |
Frequency range | 2G GSM Quadband: 850/900/1800/1900 MHz | |
Transmission interval | 5 min ... 24 h | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017 EN 301 489-19 V2.1.0:2017 EN 301 489-52 V1.1.0:2016 |
|
Radio and telecommunication terminal equipment | ||
Directive 2014/53/EU | EN 301 511 V12.5.1:2017 EN 300 328 V2.1.1:2016 EN 303 413 V1.1.1:2017 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012-09 | |
Conformity | ||
Mech. capacity | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Shock resistance | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Vibration resistance | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Climatic conditions | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 / IP67 | |
Material | ||
Housing | PC (UL94-V0) | |
Transducer | PTFE coated housing: PBT |
|
Mass | 600 g | |
Dimensions | ||
Height | 74 mm | |
Width | 81 mm | |
Length | 182 mm | |
Factory settings | ||
Beam width | medium | |
Transmission interval | 24 h | |
Measurement interval | 8 h |
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
The wireless ultrasonic sensor can be used for remote monitoring of fill level. The fill level, but also other parameters such as geo data and sensor status data, are measured at definable time intervals and stored until the next telemetry data transfer.
The stored sensor data are transferred in definable time intervals wirelessly to a counterpart on the Internet from where they are available for pure display or further processing.
Brief Instructions | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 521 KB |
CAD | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 11207 KB |