Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Pobierz pełną kartę katalogową w formie pliku PDF:
General specifications | ||
---|---|---|
Signal type | Analog input | |
Supply | ||
Connection | Power Rail or terminals 23+, 24- | |
Rated voltage | 19 ... 30 V DC | |
Rated current | approx. 120 mA at 24 V DC | |
Power dissipation | 2.3 W | |
Power consumption | 2.9 W | |
HART signal channels (intrinsically safe) | ||
Conformity | HART field device input (revision 5 to 7) | |
Interface | ||
Programming interface | programming socket | |
Input | ||
Connection side | field side | |
Connection | terminals 1, 2, 3, 4, 5, 6 | |
Open circuit voltage/short-circuit current | typ. 24 V / 28 mA | |
Input resistance | 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6) | |
Available voltage | ≥ 15.5 V at 20 mA, short-circuit protected | |
Output | ||
Connection side | control side | |
Connection | output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21 | |
Output signal | analog | |
Voltage range | 5 ... 30 V , sink mode from external supply | |
Current range | 4 ... 20 mA , (source or sink mode) | |
Load | max. 650 Ω , source mode | |
Fault signal | downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement value | |
Other outputs | HART communicator on terminals 22, 24 | |
Collective error message | Power Rail and LED red | |
Transfer characteristics | ||
Output I, II, III | ||
Resolution | max. 2 µA | |
Accuracy | < 20 µA, 10 µA typ. | |
Influence of ambient temperature | < ± 2 µA/K | |
Duration of measurement/Response delay | HART message acquisition time plus 100 ms | |
Galvanic isolation | ||
Output I/II/III/power supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Indicators/settings | ||
Display elements | LEDs , display | |
Control elements | Control panel | |
Configuration | via operating buttons via PACTware |
|
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | 300 g | |
Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 | |
Height | 119 mm | |
Width | 40 mm | |
Depth | 115 mm | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | BASEEFA 07 ATEX 0174 | |
Marking | II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC |
|
Supply | ||
Maximum safe voltage | 253 V AC (Attention! The rated voltage can be lower.) | |
Equipment | terminals 1, 4/3 (with link between terminals 4 and 5) | |
Voltage | 25.2 V | |
Current | 104.9 mA | |
Power | 0.661 W | |
Internal capacitance | 1.1 nF | |
Internal inductance | 0 mH | |
Equipment | terminals 2, 5/3 | |
Voltage | < 28 V | |
Power | < 1.33 W | |
Voltage | 1.1 V | |
Current | 11.9 mA | |
Power | 4 mW | |
Internal capacitance | 0 µF | |
Internal inductance | 0 mH | |
Output I, II, III | terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe | |
Maximum safe voltage | 253 V (Attention! Um is no rated voltage.) | |
Certificate | PF 07 CERT 1142 X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Galvanic isolation | ||
Input/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
FM approval | ||
Control drawing | 116-0129 | |
IECEx approval | ||
IECEx certificate | IECEx BAS 07.0047 | |
IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27210190 |
ECLASS 12.0 | 27210190 |
ECLASS 11.0 | 27210190 |
ECLASS 10.0.1 | 27210190 |
ECLASS 9.0 | 27210190 |
ECLASS 8.0 | 27210190 |
ECLASS 5.1 | 27242692 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 39121008 |
This isolated barrier is used for intrinsic safety applications. It is a HART loop converter that provides power to transmitters or can be connected to existing HART loops in parallel.
It is able to evaluate up to four HART variables (PV, SV, TV, QV). Of those four HART variables, the data contained in any three of them can be converted to three different 4 mA ... 20 mA current signals. These loop signals can be connected to display devices or analog inputs on the process control system/ control system.
The unit is easily programmed by the use of a keypad located on the front of the unit or with the PACTware™ configuration software.
For additional information, refer to the manual and www.pepperl-fuchs.com.
Literature | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Application Report - Biological Cleaning of Wastwater and Secondary Sedimentation Stage | ENG | 566 KB | |
Application Report - Energy Generation in Wastwater Treatment Plants | ENG | 532 KB | |
Application Report - Generating Electricity in Coal-Fired Power Plants | ENG | 412 KB | |
Application Report - Sand Trap and Preliminary Sedimentation Stage | ENG | 448 KB | |
Application Report - Screening Systems in Sewage Treatment Plants | ENG | 577 KB | |
Application Report - Sicherer Brennstofftransport in Kohlekraftwerken | ENG | 391 KB | |
Application Report - Water Inlet in Wastewater Treatment Plants | ENG | 526 KB |
Brief Instructions | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Operator card KF**-HLC-**1.D* / Bedienkarte KF**-HLC-**1.D* | ALL | 981 KB | |
Safety and Security Documentation | |||
Instrukcja obsługi | POL | 167 KB | |
Manuals | |||
Manual KF**-HLC-**1.D* | ENG | 4267 KB | |
Manual | ENG | 3685 KB |
CAD | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 870 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
EPLAN macro EDZ / EPLAN Makro EDZ | ALL | EDZ | 82 KB |
Certificates | Nr. certyfikatu | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|---|
Baseefa IECEx Certificate of Conformity | IECEx BAS 07.0047 | ALL | LINK | --- |
Brasil TUV Rheinland Brazil | TÜV 13.2090 | ALL | 1210 KB | |
Canada FM | FM22CA0014X | ALL | 317 KB | |
China SITIIAS CCC Ex Certificate | 2021322316004122 (Singapore) | ALL | 1359 KB | |
Europe Baseefa ATEX Category (1) G ATEX Category (1) D | Baseefa 07 ATEX 0174 | ALL | 3311 KB | |
Europe Pepperl+Fuchs ATEX Category 3 G Certificate of Compliance | PF 07 CERT 1142X | ALL | 212 KB | |
South Africa MASC | MASC S/17-0873 | ALL | 701 KB | |
USA FM | CoC 3032427 | ALL | 84 KB | |
United Kingdom UK-Type Examination Certificate UKEX Category (1) G UKEX Category (1) D | CML 21UKEX21103 | ALL | 198 KB | |
Control Drawings | ||||
Control drawing FM / Control drawing FM | ALL | 58 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0646D | ALL | 83 KB |
Device Description Files/Drivers | Informacja o wersji | Typ pliku | Rozmiar pliku |
---|---|---|---|
DTM Collection HART Loop Converter / DTM Collection HART Loop Converter | 1.0.6.0 | ZIP | 13857 KB |
Software Tools | |||
PACTware 4.1 SP6 / PACTware 4.1 SP6 | 4.1.0.53 | ZIP | 43327 KB |
PACTware 5.0 / PACTware 5.0 | 5.0.5.31 | ZIP | 44203 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|
||||||
|
||||||
|