Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Pobierz pełną kartę katalogową w formie pliku PDF:
General specifications | ||
---|---|---|
Number of protected signal lines | 2 | |
Topology | grounded | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Electrical specifications | ||
Connection | protected area: terminals 7, 8 unprotected area: terminals 1, 2 |
|
Rated current | 250 mA | |
Leakage current | < 10 µA at 24 V and 25 °C (77 °F) , line-line | |
Nominal voltage | 24 V DC | |
Maximum continuous operating voltage | 30 V DC | |
Series resistance | < 0.5 Ω per line | |
Impulse rating | 10 kV/5 kA (category C2) 2 kV/2 kA (category D1) |
|
Impulse discharge current (10/350 µs) | 2 kA per line (2x) | |
Nominal discharge current (8/20 µs) | 5 kA per line (10x) | |
Rated surge current (8/20 µs) | 10 kA per line (1x) | |
Total discharge current (8/20 µs) | 20 kA (1x) | |
Voltage protection level | max. 100 V line-line for nominal discharge current In max. 50 V line-earth for nominal discharge current In |
|
Impulse reset time | < 30 ms | |
Insertion loss | ≤ 0.05 dB, at 0 ... 4 kHz, in 600 Ω-System ≤ 3 dB, at 0 ... 174 kHz, in 100 Ω-System |
|
Indicators/settings | ||
Labeling | space for labeling at the front | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Surge protective devices for low voltage | EN 61643-21:2001+A1:2009+A2:2013 IEC 61643-21:2001+A1:2008+A2:2012 |
|
Operating conditions | ||
Installation conditions | ||
Mounting location | indoor | |
Ambient conditions | ||
Ambient temperature | -30 ... 80 °C (-22 ... 176 °F) For usage in hazardous area observe the EC-type examination certificate. |
|
Relative humidity | 5 ... 95 % | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross section | 2 x 2.5 mm2 | |
Mass | approx. 100 g | |
Dimensions | 12.5 x 115 x 116 mm (0.5 x 4.5 x 4.6 inch) (W x H x D) | |
Height | 115 mm | |
Width | 12.5 mm | |
Depth | 116 mm | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | PTB 00 ATEX 2176 X | |
Marking | II 2(1)G Ex ia IIC T6/T5/T4 | |
Temperature class | T6 for ambient temperature ≤ 50 °C T5 for ambient temperature ≤ 70 °C T4 for ambient temperature ≤ 80 °C |
|
Voltage | 30 V | |
Current | 250 mA | |
Internal capacitance | negligible | |
Internal inductance | 200 µH | |
Certificate | PF 16 CERT 4065 X | |
Marking | II (3)D [Ex ic Dc] IIIC | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0187 (cCSAus) | |
IECEx approval | ||
IECEx certificate | IECEx BAS 14.0010X | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27171202 |
ECLASS 12.0 | 27171202 |
ECLASS 11.0 | 27130805 |
ECLASS 10.0.1 | 27130805 |
ECLASS 9.0 | 27130805 |
ECLASS 8.0 | 27130805 |
ECLASS 5.1 | 27130801 |
ETIM 9.0 | EC000941 |
ETIM 8.0 | EC000941 |
ETIM 7.0 | EC000941 |
ETIM 6.0 | EC000941 |
ETIM 5.0 | EC000941 |
UNSPSC 12.1 | 39121610 |
The device limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal loop voltage during the duration of the overvoltage pulse.
The device is HART transparent.
The device is mounted on a 35 mm DIN mounting rail according to EN 60715.
Note:
Always connect the device to high-quality ground connections. The device must have the same potential as the devices it protects. Install the ground system in accordance with the applicable regulations.
Safety and Security Documentation | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Instrukcja obsługi | POL | 158 KB | |
Manual | ENG | 2244 KB | |
Manuals | |||
Brief Instructions - Surge Protection Barriers | ENG | 876 KB | |
Manual P-LB,F-LB,K-LB | ENG | 1151 KB |
CAD | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 951 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Nr. certyfikatu | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|---|
Baseefa IECEx Certificate of Conformity | IECEx BAS 14.0010X | ALL | LINK | --- |
Canada, USA CSA | CoC 1128189 | ALL | 62 KB | |
China SITIIAS CCC Ex Certificate | 2020322304002602 (Bintan) | ALL | 1100 KB | |
Europe PTB ATEX Category (1) 2 | PTB 00 ATEX 2176X | ALL | 946 KB | |
Europe Pepperl+Fuchs ATEX Category (3) D | PF 16 CERT 4065 X | ALL | 601 KB | |
India PESO (India) CCOE | A/P/HQ/KA/104/5871 (P507630) | ALL | 101 KB | |
exida Functional Safety Assessment | P+F 11-10-085 R036 V1R0 | ALL | 477 KB | |
Control Drawings | ||||
Control drawing CSA / Control drawing CSA | ALL | 179 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0968C | ALL | 92 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
Szukasz konkretnego produktu z określonym poziomem SIL/PL? Nasze narzędzie wyszukiwania przedstawia przegląd urządzeń z określonym poziomem bezpieczeństwa, w tym poziom nienaruszalności bezpieczeństwa (Safety Integrity Level — SIL) oraz poziom zapewnienia bezpieczeństwa (Performance Level — PL) — wypróbuj je!