Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Terminal Boxes Ex e, with Window, Glass-Fiber Reinforced Polyester (GRP) GR.CSW*

GR.CSW*
  • Glass-fiber reinforced polyester (GRP) enclosure
  • Window with flap for time-saving inspection of the internal components
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Ex eb, Ex ia and Ex tb certified
  • Withstands temperatures down to -50 °C
  • Customizable configuration of terminals, cable entries and cable gland types as per specification

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  GR.CSW*

Opis produktu
Terminal Boxes Ex e, with Inspection Window and Protective Flap, Glass-Fiber Reinforced Polyester (GRP)
Electrical specifications
Operating voltage1000 V AC max.
Operating currentapplication-specific
Mechanical specifications
Enclosure coverfully detachable , window with flap , optional hinges
Cover fixingsee data table
Screwsstainless steel combination Phillips and slotted screw
Cover sealfoamed silicone
Degree of protectionIP66
Cable entrysee data table
Number of cable entriessee data table
Terminal assembly
Number of railssee data table
Terminal typeStandard see PDF datasheet, other terminal types optional
Number of terminals per railsee data table
Material
Enclosurecarbon loaded, antistatic glass-fiber reinforced polyester (GRP)
Finishinherent color black
Grounding plate2 mm or 5 mm brass optional
Masssee data table
valid for empty enclosure, will increase according to integrated components
Dimensionssee data table
Mountingsee data table
Groundingnone as standard
optional M6 or M8 internal/external brass nickel-plated grounding bolt
optional M6 or M8 internal/external stainless steel grounding bolt
Ambient conditions
Ambient temperature-40 ... 55 °C (-40 ... 131 °F)
Data for application in connection with hazardous areas
EU-type examination certificateCML 16 ATEX 3009X
MarkingEx-Hexagon II 2 GD
Ex eb IIC T* Gb
Ex ib IIC T* Gb
Ex tb IIIC T** °C Db
T6/T80 °C @ Ta +40 °C
T5/T95 °C @ Ta +50 °C
T4/T130 °C @ Ta +55 °C
International approvals
IECEx approvalIECEx CML 16.0008X
UKCA approvalCML 22 UKEX 2550X
Conformity
Degree of protectionEN 60529
CE marking0102
General information
Ordering informationThis device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Optional accessoriesM6 or M8 internal/external brass nickel-plated grounding bolts
M6 or M8 internal/external stainless steel grounding bolts
grounding plate, brass
mounting plate, stainless steel
hinges, polyamide
mounting block for DIN mounting rail, polyamide
engraved traffolyte tag label
engraved AISI 316L stainless steel tag label
color in-fill stainless steel tag label

Classifications

SystemClasscode
ECLASS 13.027180502
ECLASS 12.027180502
ECLASS 11.027180502
ECLASS 10.0.127180502
ECLASS 9.027180502
ECLASS 8.027180508
ECLASS 5.127180502
ETIM 9.0EC002503
ETIM 8.0EC002713
ETIM 7.0EC002713
ETIM 6.0EC002713
ETIM 5.0EC002503
UNSPSC 12.139121314

Details: GR.CSW*

Function

The GR.CSW* series can be equipped with various types and quantities of terminals, entry devices and accessories. Pepperl+Fuchs solution engineering teams provide any custom configurations including combinations of terminals and controls.

This standardized enclosure series for all Pepperl+Fuchs products consists of carbon-loaded, glass-fiber reinforced polyester with stainless steel cover screws. The enclosure series provides an anti-static, UV stabilized and corrosion resistant solution. Many features provide for easy installation and handling.

The integrated window allows easy inspection of the internal components without opening the device and without a hot work permit, thus providing significant time and cost savings. A spring-loaded flap protects the window during operation of the plant.

The enclosures are certified for operation in low temperatures of down to -50 °C and can therefore be used in many applications as a replacement for stainless steel.

Informative Literature: GR.CSW*

Language Selection:
LiteratureJęzykTyp plikuRozmiar pliku
Product Information - New GR Series GRP Enclosures for Terminal Boxes and Control StationsENGPDF1053 KB

Product Documentation: GR.CSW*

Language Selection:
Brief InstructionsJęzykTyp plikuRozmiar pliku
Brief Instructions - Terminal Boxes Series GR.TB*POLPDF491 KB

Approvals: GR.CSW*

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
CML IECEx Certificate of ConformityIECEx CML 16.0008XALLLINK---
Europe CML ATEXCML 16ATEX3009XALLPDF298 KB
UK-Type Examination CertificateCML 22UKEX2550XALLPDF264 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3934BALLPDF441 KB