General specifications |
Signal type | Digital Output |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 3 |
Supply |
Rated voltage | 0-signal: -3 ... 3 V DC , loop powered 1-signal: 20 ... 26.5 V DC , loop powered |
Power dissipation | < 1.5 W |
Power consumption | < 1.5 W |
Input |
Connection side | control side |
Connection | Input terminals 7, 8 ; test input terminals 10, 11, 12 |
Pulse/Pause ratio | min. 20 ms / min. 20 ms |
Test input | see functional safety manual |
Signal level | 0-signal: -3 ... 3 V DC 1-signal: 20 ... 26.5 V |
Rated current | 45 ... 50 mA |
Output |
Connection side | field side |
Connection | output I (ETS): terminals 2, 3 output II (DTS): terminals 4, 5, 6 output I and II (DPS): terminals 2, 3, 4, 5, 6 |
Contact loading | 253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load |
Minimum switch current | 2 mA / 24 V DC |
Energized/De-energized delay | approx. 10 ms / approx. 5 ms |
Mechanical life | 5 x 106 switching cycles |
Fuse rating | 2.5 A (max. 5 A) recommended maximum utilization of the fuse: 80 % |
Transfer characteristics |
Switching frequency | < 10 Hz |
Galvanic isolation |
Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Output/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings |
Display elements | LEDs |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Low voltage | |
| Directive 2014/35/EU | EN 61010-1:2010 |
Conformity |
Electromagnetic compatibility | NE 21:2012 |
Degree of protection | IEC 60529:2013 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
Mechanical specifications |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 100 g |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas |
Certificate | PF 15 CERT 3844 X |
| Marking | II 3G Ex nA nC IIC T4 Gc [device in zone 2] |
Output | |
| Contact loading | 50 V AC/4 A; 30 V DC/4 A , see derating curves for Zone 2 |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010 |
General information |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |