* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
SU19/110/115/126a
Product Description
Classic Series fiber optic sensor with display, master module, push-pull output, fixed cable
General specifications
Sensor range
up to 150 mm (KLR-C02-2,2-2,0-K146)
Detection range
up to 450 mm (KLE-C01-2,2-2,0-K116)
Light source
LED
Light type
modulated visible red light , 660 nm
Ambient light limit
10000 Lux
Gang mounting
maximum 20 units
Functional safety related parameters
MTTFd
500 a
Mission Time (TM)
20 a
Diagnostic Coverage (DC)
0 %
Indicators/operating means
Operation indicator
Power on: static illumination , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz)
Diagnostics indicator
7-segment display
Function indicator
LED yellow: static illumination switching state, flashes when falling short of the operating reserve
Control elements
Button (Mode) for menu choice ; Button (Set) for Teach-In ; Button (Up/Down) for fine adjusting and parameterization
Electrical specifications
Operating voltage
10 ... 30 V DC
Ripple
10 %
No-load supply current
≤ 30 mA
Output
Stability alarm output
1 push-pull (4 in 1) output NPN/PNP , short-circuit protected
Switching type
light/dark on selectable programmable
Signal output
1 push-pull (4 in 1) output NPN/PNP , short-circuit protected
Switching voltage
max. 30 V DC
Switching current
max. 100 mA , resistive load
Voltage drop
≤ 2 V DC at 100 mA ; ≤ 0.7 V at 10 mA
Switching frequency
High speed mode: 16 kHz , Standard mode: 3 kHz , High resolution: 250 Hz ~ 3 kHz (selection by the sensor), Automatic: 250 Hz , Glass mode: 250 Hz
Response time
High speed mode: 30 µs , Standard mode: 160 µs , High resolution: 2 ms , Automatic: 160 µs ~ 2 ms (choice by the sensor), Glass mode: 2 ms
Repeat accuracy
≤ 0.5 % of adjusted sensor range
Timer function
ON-delay, OFF-delay, one shot, pulse extension ; adjustable 0 ... 999 ms in 1 ms increments
Conformity
Product standard
EN 60947-5-2
Approvals and certificates
UL approval
cULus Listed, Class 2 Power Source, Type 1 enclosure
CCC approval
CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature
-10 ... 55 °C (14 ... 131 °F)
Storage temperature
-20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Degree of protection
IP50
Connection
2 m PVC cable, 4 x 0,14 mm2
Material
Housing
PC
Mass
45 g
Dimensions
Height
34.5 mm
Width
9 mm
Depth
62.3 mm
Classifications
System
Classcode
ECLASS 13.0
27270905
ECLASS 12.0
27270905
ECLASS 11.0
27270905
ECLASS 10.0.1
27270905
ECLASS 9.0
27270905
ECLASS 8.0
27270905
ECLASS 5.1
27270905
ETIM 9.0
EC002651
ETIM 8.0
EC002651
ETIM 7.0
EC002651
ETIM 6.0
EC002651
ETIM 5.0
EC002651
UNSPSC 12.1
39121528
Details:
SU19/110/115/126a
Function
The fiber optics amplifier SU19 with display was developed to set a benchmark with the most comfortable and user-friendly interface. This simplicity of the settings decreases the costs of ownership significantly.
The whole Teach-In process of objects is time-saving due to an easy Teach-In algorithm. The high resolution 4-digit percentage display indicates current values and thresholds with highest accuracy. Wire-saving and the replacement of devices is designed user-friendly and time-saving due to gang mounting on the rear.