Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Descargue la hoja de datos completa en PDF:
Extracto de la hoja de datos: Información técnica del
ICA-AO-I/U-IO-V1
Descripción del producto |
IO-Link converter with analog output (current/voltage) |
General specifications |
UL File Number | E223772 |
Functional safety related parameters |
MTTFd | 246 a |
Indicators/operating means |
LED 1 | Device status, diagnostics |
LED 2 | IO-Link status |
Electrical specifications |
Rated operating voltage | 18 ... 30 V |
Nominal voltage | 24 V DC |
Nominal current | 230 mA |
Current consumption | typ. 30 mA |
Surge protection | Category II |
Interface |
Interface type | IO-Link |
IO-Link revision | 1.1 |
Device ID | 0x0F0502 (984322) |
Transfer rate | COM2 (38.4 kBit/s) |
Min. cycle time | 2.3 ms |
Process data width | 16 bits / 2 bytes |
SIO mode support | no |
Compatible master port type | A, B |
Output |
Number/Type | 1 analog output for actuators with analog input |
Resolution | ADC: 24 bit Process data: 16 bit |
Accuracy | 0.1 % FS at 25 °C |
Measuring range | Current output or voltage output, configurable: 0 mA…20 mA 4 mA…20 mA 0 V…10 V -10 V…10 V |
Sensor supply | 17 … 29.8 V DC ≤ 200 mA |
Output filter | Average determination of process data, parameterizable |
Temperature influence | 45 ppm/°K |
Sampling rate | max. 200 Hz |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61000-6-2:2005, EN 61000-6-4:2007+A1:2011 |
Standard conformity |
Degree of protection | EN 60529:2000 |
Fieldbus standard | IEC 61131-9 / IO-Link V1.1 |
Emitted interference | EN 61000-6-4 |
Noise immunity | EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6 |
Shock resistance | EN 60068, Part 2-6, Part 2-27 |
Ambient conditions |
Ambient temperature | -30 ... 70 °C (-22 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | max. 85 % |
Climatic conditions | Climatic class 3K3 |
Altitude | 0 ... 2000 m |
Shock and impact resistance | 50 g, 11 ms, all axes |
Pollution degree | 3 |
Mechanical specifications |
Degree of protection | IP67 |
Connection | IO-Link M12, A-coded Input M12, A-coded |
Material | |
| Contacts | Zinc, CuNi plated |
| Housing | Plastic PC + PBT |
Mass | 44 g |
Dimensions | |
| Height | 32.3 mm |
| Width | 15 mm |
| Length | 77.2 mm |
Construction type | Field housing |
Classifications
System | Classcode |
ECLASS 13.0 | 27242601 |
ECLASS 12.0 | 27242601 |
ECLASS 11.0 | 27242601 |
ECLASS 10.0.1 | 27242601 |
ECLASS 9.0 | 27242601 |
ECLASS 8.0 | 27242601 |
ECLASS 5.1 | 27242601 |
ETIM 9.0 | EC001597 |
ETIM 8.0 | EC001597 |
ETIM 7.0 | EC001597 |
ETIM 6.0 | EC001597 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 32151705 |
Details:
ICA-AO-I/U-IO-V1
Product Documentation:
ICA-AO-I/U-IO-V1
Design / Simulation:
ICA-AO-I/U-IO-V1
Approvals:
ICA-AO-I/U-IO-V1
Software:
ICA-AO-I/U-IO-V1
Productos asociados:
ICA-AO-I/U-IO-V1
Accessory of |
|
|
|
Ethernet IO-Link module with eight IO-Link portsfa |
|
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputsfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputsfa |
|
|
|
|
PROFINET and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa |
|
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa |
|
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa |
|
|
|
|
Ethernet IO-Link master with PROFINET S2 redundancyfa |
|
|
|
|
Ethernet IO-Link module with 4x Class A and 4x Class B IO-Link portsfa |
|
|
|
|
Ethernet IO-Link module with 8 inputs/outputsfa |
|
|
|
|
EtherNet/IP and Modbus IO-Link master with 4 x IO-Link Class A and 4 x IO-Link Class B portsfa |
|
|
|
|
Ethernet IO-Link module with 8 inputs/outputsfa |
|
|
|
|
Firmware variant from ICE3-8IOL-G65L-V1D with Modbus enabled by defaultfa |
|
Accessories |
|
|
|
torque screwdriver (0.6 Nm)fa |
|
|
|
|
plug-in cap M12fa |
|
|
|
|
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa |
|