Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

RFID read/write device IQT3-FP-IO-V1

IQT3-FP-IO-V1
  • Range up to 30 cm
  • Operating frequency 13.56 MHz
  • Conforms to ISO 15693
  • LEDs as function indicators
  • Multi-tag reading of up to 20 tags ensures increased productivity
  • For connection to IO-Link master
  • Degree of protection IP67

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  IQT3-FP-IO-V1

Descripción del producto
HF RFID read/write device with IO-Link in accordance with ISO 15693
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 300 mm (see manual)
Write distance0 ... 300 mm (see manual)
Widthmax. 300 mm
MTBF90 a (Operation at +40 °C)
Indicators/operating means
LED greenSolid green: Ready for operation, no IO-Link communication
Flashing green (1 Hz): IO-Link operation
LED yellowRead/write operation successful
LED redstatus display
LED blueTransmission mode
Electrical specifications
Operating voltage18 ... 30 V DC (IO-Link)
Current consumptionmax. 700 mA ( NOTE: Check the power supply capabilities at the port of the master and wire gauge of the connection cable in order to assure stable communication. )
Interface
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Process dataInput 32 Byte
Output 32 Byte
Vendor ID1 (0x0001)
Device ID4195073 (0x400301)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time4 ms
SIO mode supportno
Compatible master port typeClass A
Class B
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
UL approvalE468231
cULus Listed, Class 2 Power Source, Type 1 enclosure
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
MIC approvalAC-24025
ACMA approvalCERT-7286
WPC approvalETA-SD-20230908020
Radio approvalUSA: Contains FCC ID IREIQR3FP
Canada: Contains IC 7037A-IQR3FP
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods, adjustable)
-25 ... 55 °C (-13 ... 131 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPA 6.6
Encapsulation compoundWEVO 403FL/300
Installation
Distance between two heads≥ 750 mm
Mass385 g
Dimensions
Height40 mm
Width80 mm
Length80 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IQT3-FP-IO-V1

Product Documentation: IQT3-FP-IO-V1

Seleccionar idioma:
ManualsIdiomaTipo de archivoTamaño
Manual IQT3-FP-IO-V1ENGPDF4172 KB
Parameter Information
IO-Link Parameter Datasheet IQT3-FP-IO-V1 / IO-Link-Parameter-Datenblatt IQT3-FP-IO-V1ALLPDF527 KB

Design / Simulation: IQT3-FP-IO-V1

Seleccionar idioma:
CADIdiomaTipo de archivoTamaño
CAD 3-D / CAD 3-DALLSTP1062 KB

Approvals: IQT3-FP-IO-V1

Seleccionar idioma:
CertificatesNúmero de CertificadoIdiomaTipo de archivoTamaño
Canada Radio Approval7037A-IQR3FPALLPDF324 KB
Canada, USA ULUL-US-2401706-0ALLPDF285 KB
IO-Link Manufacturer DeclarationCERT-7017ALLPDF363 KB
India Radio ApprovalETA-SD-20230908020ALLPDF61 KB
Japan Radio ApprovalAC-24025ALLPDF208 KB
USA FCC ApprovalIREIQR3FPALLPDF342 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-7356ALLPDF105 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7357ALLPDF103 KB
Australia Declaration of ConformityACMA Supplier's declaration of conformityALLPDF168 KB
FCC Suppliers Declaration of Conformity / FCC-Konformitätserklärung des LieferantenDOC-7358ALLPDF276 KB

Productos asociados: IQT3-FP-IO-V1

Accessories

Ethernet IO-Link module with eight IO-Link portsfa

EtherNet/IP IO-Link master with 8 inputs/outputsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable black, UL approvedfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PUR cable black, UL-approved, drag chain suitable, torsion resistantfa
Dispositivo de lectura/escritura RFID IUT-F190-B40 con interfaz Ethernet industrial y API REST

Conozca el nuevo IUT-F190-B40, que está diseñado para rangos de detección medios y se puede integrar de forma rápida y sencilla en los sistemas TO y TI…

Visite el Hub RFID

Visite nuestro "Hub RFID: esta página web especial es una base de conocimientos sobre RFID. Obtenga respuestas a preguntas frecuentes y aprenda sobre las aplicaciones RFID más habituales...