Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Pobierz pełną kartę katalogową w formie pliku PDF:
Opis produktu |
---|
Premium industrial door opener with the ability to differentiate between people and vehicles, can be operated remotely, detection range 9 m x 6.5 m, max. installation height 7 m, black housing, 2 relay contact outputs, cable connection |
General specifications | ||
---|---|---|
Sensing range | 9000 x 6500 mm (d x w) at installation height of 5000 mm and 45° angle 10000 x 5500 mm (d x w) at installation height of 7000 mm and 45° angle |
|
Function principle | Microwave module | |
Detection speed | min. 0.1 m/s | |
Marking | FCC | |
Setting angle | -90 ... 90 ° in 15 ° increments | |
Operating frequency | 24.15 ... 24.25 GHz K-Band | |
Operating mode | Radar motion sensor | |
Transmitter radiated power (EIRP) | < 13 dBm | |
Functional safety related parameters | ||
MTTFd | 620 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | LED red/green | |
Control elements | Programming push-button for selection of operating modes : direction detection , cross-traffic suppression , Vehicle detection , Switching type , relay hold time | |
Control elements | Programming via 2 keys , alternative via remote control (Accessories ordered separately) | |
Electrical specifications | ||
Operating voltage | 12 ... 36 V DC , 12 ... 28 V AC | |
No-load supply current | ≤ 50 mA at 24 V DC | |
Power consumption | ≤ 1 W | |
Output | ||
Switching type | NO/NC | |
Signal output | 2 relay outputs | |
Switching voltage | max. 48 V AC / 48 V DC | |
Switching current | max. 0.5 A AC / 1 A DC | |
Switching power | max. 24 W / 60 VA | |
De-energized delay | 0.5 ... 300 s adjustable | |
Approvals and certificates | ||
FCC approval | FCC Rules part 15 / This device can be used in the USA. RSS-310 of Industry Canada / This device can be used in Canada. |
|
Approvals | Use in countries within the European Union is not permitted. In other countries, all applicable national regulations must be observed. | |
Ambient conditions | ||
Operating temperature | -30 ... 60 °C (-22 ... 140 °F) | |
Storage temperature | -30 ... 60 °C (-22 ... 140 °F) | |
Relative humidity | max. 90 % non-condensing | |
Mechanical specifications | ||
Mounting height | 2500 ... 7000 mm | |
Degree of protection | IP67 | |
Connection | plug-in screw terminals 4-pin and 2-pin , 8 m connecting cable included with delivery | |
Material | ||
Housing | Polycarbonate (PC) , anthracite | |
Mass | 650 g | |
Dimensions | with Mounting bracket : 131 mm x 73 mm x 136 mm | |
Height | 73 mm | |
Width | 131 mm | |
Depth | 98 mm | |
Suitable series | ||
Series | RAVE |
System | Classcode |
---|---|
ECLASS 13.0 | 27274501 |
ECLASS 12.0 | 27280890 |
ECLASS 11.0 | 27280890 |
ECLASS 10.0.1 | 27280890 |
ECLASS 9.0 | 27280890 |
ECLASS 8.0 | 27280890 |
ECLASS 5.1 | 27270990 |
ETIM 9.0 | EC004807 |
ETIM 8.0 | EC000138 |
ETIM 7.0 | EC000138 |
ETIM 6.0 | EC000138 |
ETIM 5.0 | EC000138 |
UNSPSC 12.1 | 39121528 |
The RAVE-D is a radar sensor for harsh industrial environments. The robust housing with IP67 degree of protection makes it the ideal door opener up to a height of 7 m.
The housing concept enables time-saving mounting due to the convenient wall bracket and locking plate for adjusting the detection field.
Differentiated detection of people and vehicles provides targeted door opening. This enables optimized transport routes and energy savings.
Accessories | ||||||
---|---|---|---|---|---|---|
|