Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Pobierz pełną kartę katalogową w formie pliku PDF:
Opis produktu |
---|
Control interface unit IDENTControl with serial interface RS-232 |
General specifications | ||
---|---|---|
Number of read/write heads | max. 4 alternative 2 read/write heads and 2 trigger sensors |
|
UL File Number | E87056 | |
MTBF | 95 a (Operation at +40 °C) | |
Indicators/operating means | ||
LEDs 1, 2, 3, 4 | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
|
LED PWR/ERR | green: power on red: Hardware fault |
|
LED UL | green: Interface Power ON/OK | |
LED TxD | green: flashes in rhythm with the transmitted data | |
LED RxD | green: flashes in rhythm of receiving data | |
LC display | two-line multi-function display with 12 characters per line configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands |
|
Button | 4 keys: ESC, up, down and return | |
Electrical specifications | ||
Rated operating voltage | 20 ... 30 V DC , PELV | |
Ripple | ≤ 10 % at 30 V DC | |
Current consumption | ≤ 2 A incl. read/write heads | |
Power consumption | 2.5 W Without read/write heads | |
Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff | |
Interface | ||
Physical | RS 232 | |
Protocol | ASCII | |
Transfer rate | 1200; 2400; 4800; 9600; 19200; 38400 Bit/s | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | IEC/EN 63000 | |
Standard conformity | ||
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -30 ... 80 °C (-22 ... 176 °F) | |
Climatic conditions | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 |
|
Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
|
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M6 earthing screw RS 232: M12 plug connection |
|
Material | ||
Housing | powder coated aluminum | |
Installation | snap-on to 35 mm standard rail or screw fixing | |
Mass | approx. 1000 g | |
Dimensions | ||
Height | 73 mm | |
Width | 105 mm | |
Length | 148 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27280401 |
ECLASS 12.0 | 27280401 |
ECLASS 11.0 | 27280401 |
ECLASS 10.0.1 | 27280401 |
ECLASS 9.0 | 27280401 |
ECLASS 8.0 | 27280401 |
ECLASS 5.1 | 27280401 |
ETIM 9.0 | EC002998 |
ETIM 8.0 | EC002998 |
ETIM 7.0 | EC002998 |
ETIM 6.0 | EC002998 |
ETIM 5.0 | EC002998 |
UNSPSC 12.1 | 43211710 |
The innovative concept of the RFID identification system IDENTControl from Pepperl+ Fuchs has many advantages in comparison to other systems. The core piece of the system is the evaluation unit IDENTControl.
Thanks to the integrated interfaces for all standard field bus systems such as PROFIBUS, EtherNet, PROFINET IO, DeviceNet, serial connections (RS 232/RS 485/RS 422) and numerous connection options for inductive write/read heads as well as microwave antennas, the evaluation unit IDENTControl can be adjusted to your needs in a flexible and easy manner.
LEDs indicate operating power and bus communication, connected write/read heads and active write/read commands.
Mounting the unit onto DIN mounting rails is easy thanks to the snap-fits on the back of the housing of the evaluation unit IDENTControl .
With its L-shaped housing, the evaluation unit including bus connector fits into a 120 mm grid in the switch cabinet. The mounting depth of 70 mm furthermore enables installation in flat switch boxes with a depth of only 100 mm.
There are 3 further mounting holes for field mounting.
Literature | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Application Report - RFID Systems in Industrial Metal Stamping | ENG | 1773 KB |
Brief Instructions | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
Brief Instructions - IC-KP-* | ENG | 1019 KB | |
Device mounting / Gerätemontage | ALL | 917 KB | |
Manuals | |||
Manual IC-KP-R2-V1 | ENG | 1294 KB | |
Manual Read / Write Ranges and Passing Speeds RFID | ENG | 3640 KB |
CAD | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 7645 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Nr. certyfikatu | Język | Typ pliku | Rozmiar pliku |
---|---|---|---|---|
Canada, USA UL | CoC UL-CA-L87056-31-61115002-0 / UL-US-L87056-11-61115002-0 | ALL | 561 KB | |
Korea Radio Approval | MSIP-RE1-PF1-ICKPR2V1 | ALL | 360 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-1845C | ALL | 108 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-7045 | ALL | 107 KB | |
Australia Declaration of Conformity | CERT-3756 | ALL | 744 KB |
Software Tools | Informacja o wersji | Typ pliku | Rozmiar pliku |
---|---|---|---|
Software RFIDControl Demo / Software RFIDControl Demo | V 1.5.3 | ZIP | 5253 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|