Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Faça o download das folhas de dados em PDF:
Descrição do Produto |
---|
Automation light grid with beam spacing of 17 mm, IO-Link interface, push-pull output, fixed cable with M12 plug |
General specifications | ||
---|---|---|
Effective detection range | Standard : 0.3 ... 6 m Option /35: 0.5 ... 8 m |
|
Threshold detection range | Standard : 7.5 m Option /35: 10 m |
|
Light source | IRED | |
Light type | modulated infrared light , 850 nm | |
Field height | see Table 1, max. 3200 mm | |
Beam crossover | Factory setting: three beam crossing, deactivateable | |
Beam blanking | adjustable max. 2 fixed suppressible beam areas (blanking) | |
Beam spacing | 16.67 mm | |
Number of beams | see Table 1, max. 193 | |
Operating mode | Emitter: Emitter power adjustable in two ranges | |
Optical resolution | without beam crossover: 17 mm with beam crossover: 8.5 mm with in 25% and 75% of the range |
|
Opening angle | 10 ° | |
Ambient light limit | > 50000 Lux (if external light source is outside the opening angle) | |
Functional safety related parameters | ||
MTTFd | 25 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 60 % | |
Indicators/operating means | ||
Operation indicator | Power on: LED green, statically lit , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) | |
Function indicator | Emitter: Yellow LED, illuminates at high emitting power, off at low emitting power Receiver: Yellow LED: illuminates when an object is detected flashes when falling short of the operating reserve (4 Hz) Error message: Yellow LED flashes (8 Hz) in emitter and receiver |
|
Control elements | Receiver: 2 touch buttons for programming | |
Parameterization indicator | IO link communication: green LED goes out briefly (1 Hz) | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC | |
Ripple | 10 % | |
No-load supply current | Emitter ≤: 50 mA Receiver: ≤ 150 mA (without outputs) |
|
Time delay before availability | see Table 1, max. 3 s | |
Interface | ||
Interface type | IO-Link | |
Protocol | IO-Link V1.0 | |
Mode | COM2 (38.4 kBit/s) | |
Input | ||
Test input | Emitter switch-off with +UB or 0 V at pin 4 (emitter) | |
Function input | Range input activation from 1.6 m (or 2 m in case of option /35) with +UB or 0 V on pin 2 (emitter) Teach-In input for programming on pin 8 (receiver) |
|
Output | ||
Stability alarm output | Stability Control (SC) 1 PNP, short-circuit protected, reverse polarity protected on pin 2 (receiver) | |
Switching type | Factory setting: dark on , Switchable to light-on mode | |
Signal output | Switching output (detection field C/Q) 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected on pin 4 (receiver), Height monitoring (H1, H2. H3) 3 push-pull (4 in 1) outputs, short-circuit proof, reverse polarity protected on pin 5, pin 6, pin 7 (receiver) |
|
Switching threshold | Factory setting: The signal tracking for the threshold value is deactivated, increasing the optical resolution by a maximum of 4 mm; switchable to active signal tracking | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA | |
Voltage drop | ≤ 2 V DC | |
Switching frequency | see Table 1, max. 129 Hz | |
Response time | see Table 1, max. 16 ms | |
Timer function | Off-delay programmable from 0 ... 1.25 s in 5 ms steps (adjustment via IO-Link only) | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
Protection class | III ( IEC 61140 ) | |
UL approval | cULus Listed | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | Standard : -10 ... 60 °C (14 ... 140 °F) Option /146: -30 ... 60 °C (-22 ... 140 °F) |
|
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Conductor cross section | min. 0.25 mm2 | |
Housing length L | see Table 1, max. 3360 mm | |
Degree of protection | IP67 | |
Connection | Emitter: connecting cable with 4-pin, M12 x 1 connector , 330 mm total length Receiver: connecting cable with 8-pin, M12 x 1 connector , 350 mm total length |
|
Material | ||
Housing | extruded aluminum section , Silver anodized | |
Optical face | Plastic pane , Polycarbonate | |
Mass | see Table 1, max. 1750 g (per profile) | |
Dimensions | ||
Width | 20 mm | |
Depth | 30.5 mm | |
Cable length | max. 30 m |
System | Classcode |
---|---|
ECLASS 13.0 | 27270910 |
ECLASS 12.0 | 27270910 |
ECLASS 11.0 | 27270910 |
ECLASS 10.0.1 | 27270910 |
ECLASS 9.0 | 27270910 |
ECLASS 8.0 | 27270910 |
ECLASS 5.1 | 27270910 |
ETIM 9.0 | EC002549 |
ETIM 8.0 | EC002549 |
ETIM 7.0 | EC002549 |
ETIM 6.0 | EC002549 |
ETIM 5.0 | EC002549 |
UNSPSC 12.1 | 39121528 |
Literature | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
Brochure - Automation Light Grids: LGS and LGM Series | ENG | 1965 KB |
Product information | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Manuals | |||
Manual automation light grid LGS | ENG | 3054 KB |
Certificates | Número do Certificado | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|---|
Canada USA UL Ordinary Location | E87056 | ALL | LINK | --- |
Canada USA UL Ordinary Location | UL-CA-2134531-0 / UL-US-2141152-0 | ALL | 544 KB | |
IO-Link Manufacturer Declaration | PF 13 CERT 2629 | ALL | 230 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0227C | ALL | 304 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-5336 | ALL | 228 KB |
Device Description Files/Drivers | Informações | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
IODD for LGS series / IODD für LGS-Serie | V1.03.004 / 2018-08-15 | ZIP | 2664 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|