Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
A teljes adatlap letöltése PDF formátumban:
HART signal channels (non-intrinsically safe) | ||
---|---|---|
Load resistor | 220 Ω , switchable on | |
Interface | ||
Type | multiplexer connection : IDC plug, 26-pin | |
Signal lines | ||
Rated current | max. 30 mA per channel | |
Indicators/settings | ||
Control elements | DIP switch |
|
DIP switch | selection of operating mode: - ON: without load resistor - OFF: with load resistor |
|
Factory setting | DIP switches S1 and S2: ON | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2017 For further information see system description. |
|
Degree of protection | IEC 60529:2001 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ambient conditions | ||
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) | |
Storage temperature | -15 ... 50 °C (5 ... 122 °F) | |
Relative humidity | ≤ 93 % non-condensing | |
Shock resistance | 15 g , 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | ||
Field side | screw terminals , green | |
Control side | screw terminals , green HART : 1 x IDC plug, 26-pin |
|
Core cross section | 0.25 ... 1.5 mm2 (24 ... 16 AWG) | |
Material | ||
Housing | PVC | |
Mass | approx. 210 g | |
Dimensions | 110 x 125 x 61 mm (4.3 x 4.9 x 2.4 inch) (W x H x D) | |
Height | 125 mm | |
Width | 110 mm | |
Depth | 61 mm | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
Certificate | PF 11 CERT 1930 X | |
Marking | II 3G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-15:2010 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27210190 |
ECLASS 12.0 | 27210190 |
ECLASS 11.0 | 27210190 |
ECLASS 10.0.1 | 27210190 |
ECLASS 9.0 | 27210190 |
ECLASS 8.0 | 27210190 |
ECLASS 5.1 | 27242690 |
ETIM 9.0 | EC001485 |
ETIM 8.0 | EC001485 |
ETIM 7.0 | EC001485 |
ETIM 6.0 | EC001485 |
ETIM 5.0 | EC001485 |
UNSPSC 12.1 | 39121008 |
This HART termination board has 16 terminal blocks to connect up to 16 HART field devices.
It has an integrated, switchable 220 load resistor and an integrated ground capacitor. It also has terminal blocks for the 4 mA ... 20 mA signal to the DCS/ PLC.
A 26-pin flat cable K-HM26 is used for connection of each HART Multiplexers KFD*-HM*-16 to the termination board.
Other termination boards are available. Contact Pepperl+Fuchs for details.
Manuals | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
Manual KFD*-HM*-16 | ENG | 8323 KB |
Certificates | Tanúsítvány sz. | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|---|
Europe Pepperl+Fuchs Certificate of Compliance ATEX Category 3 | PF11CERT1930 X | ALL | 193 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-1070D | ALL | 107 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|